Intel
®
Server System R1000WF Product Family System Integration and Service Guide
10
a)
Connect the short black round cable to the 30-pin header on the server board labeled “Front
Control Panel”.
b)
Connect the 14-pin gray folded ribbon cable to the 14-pin black shrouded connector on the server
board labeled “Front Panel Video”.
c)
Each of the two previous cables should be routed as close to the chassis sidewall as possible.
d)
Route the long black round USB cable inside the cable routing channel along the chassis sidewall.
At this time,
do NOT attach the USB cable to the server board
.
6.
Install the Air Duct Side Walls and Chassis Support Bracket
The air duct sidewalls and chassis support bracket MUST be installed and fastened down in a specific order.
Do not deviate from the provided instructions.
Figure 16. Air Duct Side Wall and Support Bracket Installation
a)
Locate the two black plastic air duct sidewalls.
b)
Following the illustration above, place the left and right air duct sidewalls onto each side of the
server board (see Letter “C”)
c)
Using the captive screws on the side walls, loosely secure each to the server board (see numbers 1 &
2).
d)
Locate the Chassis Support Bracket.
e)
Following the illustration above, position the Chassis Support Bracket onto the server board,
aligning the two end mounts with the air duct sidewall mounting holes and the center mount to the
mounting hole on the server board. (See Letter “D”).
Содержание R1000WF Series
Страница 2: ...Intel Server System R1000WF Product Family System Integration and Service Guide Blank Page ...
Страница 16: ......