![Intel Omni-Path Director Class Switch Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/intel/omni-path-director-class-switch-series/omni-path-director-class-switch-series_installation-manual_2073475081.webp)
Service (SVC)
The Chassis Service (SVC) LED indicates the following condition:
•
Green
: Chassis beacon is active
•
Off: Not selected
Master
•
Green
: the module is acting as the master Management Module
•
Off: Management Module is not the Master
MRL Active
•
Green
: the mechanical release latch (MRL) thumbscrew is secured to the
management module, enabling communications with a mated management leaf
module
•
Off: the mechanical release latch (MRL) thumbscrew is not engaged, disabling
communications with a mated management leaf module
Leaf Module LEDs
Figure 66.
Leaf Module LEDs
Port LEDs
•
Green
: The external HFI link is in the Active Port State
•
Off: Link is not active
Module Status
The status LED indicates one of the following conditions:
•
Steady
Green
: the module is operating normally.
•
Blinking
Green
: LED test state.
•
Off: module is in the removable state.
Module Attention
The Attention LED indicates one of the following conditions:
2.8.2.2
Installation—Intel
®
Omni-Path Fabric
Intel
®
Omni-Path Fabric Switches Hardware
June 2019
Installation Guide
Doc. No.: H76456, Rev.: 10.0
81