ETSM / ETSU
Commissioning, Operation and Configuration
ETSM
27
10
Commissioning, Operation and Configuration
ETSM
10.1
Commissioning
The lite-managed switch ETSM is delivered pre-configured. The factory configura-
tion is set such that after powering the switch, the device transmits data to all
Ethernet ports immediately. The following settings are set as default:
•
Web interface IP address:
192.168.0.2
•
Web interface user name:
admin
•
Web interface password: password
•
Web interface access:
via any Ethernet
port
•
Ethernet ports:
activated
•
Auto-Negotiation: activated
•
VLAN, QoS, port mirroring:
deactivated
•
Link aggregation: deactivated
•
Fault contact:
Normally Open
•
Fault contact events:
V1 or V2 fault; over
temperature
•
TRAP protocol:
UDP
•
TRAP IP address: 192.168.0.1:4321
•
TRAP events:
V1 or V2 fault; over
temperature, internal fault
•
Logging function: activated
Proceed as follows for commissioning:
1.
Connect the power supply
2.
Connect the PC / notebook to one of the Ethernet ports of the device
3.
The connected PC / notebook must have the following network settings:
•
Fix IP address: 192.168.0.1
•
Subnet mask:
255.255.255.0
4.
Start a web browser and enter the IP address of the device
5.
Perform the desired configuration of the device
6.
Connect the switch with your network devices