ETSM / ETSU
Technical Information
19
7
Technical Information
7.1
Technical Data
7.1.1
Physical Features
All specified data was measured with nominal input voltage, at full load, and an
ambient temperature of 25
℃
. The limit value tolerances are subject to the usual
variations.
Physical Feature
Value
Operating voltage
9.6 V
…
60 V DC
18 V
…
30 V AC
Power consumption (V = 9.6
…
24 V)
(V = 60 V)
typ. 2.4 W / max. 2.65 W
typ. 3.9 W / max. 4.2 W
Level digital input
HIGH level = 11 ... 30 V
LOW level = 0 ... 5 V
Contact open condition: LOW
Current consumption input at HIGH
potential
Max. 4 mA at 24 V, 10 mA at 30 V
Fault contact (NO), max. switch voltage
60 V (DC) / 30 V (AC)
Fault contact (NO), max. current load
1 A at 60 V DC / 30 V AC
Weight
300 g
Dimensions (Width x Depth x Height)
65 mm x 49 mm x 105 mm
(depth with connector)
Temperature range
-40 °C
…
70 °C (operation)
-40 °C
…
85 °C (storage)
Maximum permissible humidity
10 … 95% non
-condensing
IP rating
Housing IP20, connectors IP40
Table 1 : ETSM/ETSU
–
physical features