background image

                                                                                                                                  Page 16 of 22                                                                                         Rev: 9/30/2011 1:26 PM 

 

Seen if press Down arrow 

 

Can alternate between these 2 by pressing Up and Down 

 

 

Unlinking 

1)  Press & hold Thermostat Set button until it beeps 

Thermostat Set LED blinks 

GREEN

 

Thermostat will (Beep) 
 as a responder 

2)  Press & hold Thermostat Set button to put it in unlinking 

Thermostat Set LED blinks 

RED

 

Thermostat will (Beep) 
LCD display indicates the group that you are unlinking from 

3) Press: 

 

Up arrow to unlink from Group 1, Cooling mode changes 

 

Down arrow to unlink from Group 2, Heating mode changes 

4)  Press and hold responder Set button 

Thermostat will (Beep)-(Beep) to show completion, LED off 

 

Upon entering Linking mode 

 

Содержание TempLinc 2441T

Страница 1: ...essed freely via the Internet with any web browser and supports the PDF format http www smarthome com 2441TH html Complies with Section 5 of FCC document 784748 D01 Labeling Part 15 18 Guidelines v07 where cautionary statements in the user manual may be provided over the Internet On Line Owner s Manual Containing Cautionary FCC IC Statements ...

Страница 2: ...Page 1 of 22 Rev 9 30 2011 1 26 PM TempLinc Owners Manual INSTEON Thermostat 2441T ...

Страница 3: ...rogram Button Operation 8 Thermostat Fan and Hold Button Operations 10 Thermostat Master Button Operation 11 Installation 12 Tools Needed 12 Preparation 12 Wire Connections 12 Test Operation 13 Adding a Wireless Thermostat 13 INSTEON Programming 14 Linking as a Responder 14 Linking as a Controller 14 Unlinking 16 Factory Setup Modes 17 Factory Programming Mode 18 Humidity Calibration Mode 20 Facto...

Страница 4: ...leads on a 6 cord TempLinc Features Benefits Installs and Links to other INSTEON devices in minutes Saves energy and money on bills by remotely controlling and automating your thermostat Communicates wirelessly over radio frequency RF Automatically controls remote INSTEON devices when the thermostat switches A C heat and fan on or off Reports changes in thermostat modes temperature humidity setpoi...

Страница 5: ...ge the default offset value away from 5 degrees you must use HouseLinc 4 Hold over rides a pre programmed mode 5 Fan cycles between Auto and Always On 6 Master makes the device the master temperature controller 7 Time Sensor button allows you to set the date time and select the sensors humidity to display It cycles between day time format and each sensor option 8 Program button allows you to setup...

Страница 6: ...eration Off Mode No set points are shown Up Down do not do anything Auto Mode Both cool and heat set points are shown Up Down move both together with a set gap Cool Mode Only Cool set point is shown Up Down do not do anything Heat Mode Only Heat set point is shown Up Down changes the Heat set point ...

Страница 7: ...d again The mode button is pressed A pre programmed mode is activated due to time Up Down adjust the temperature set point based on the mode you are currently in inside Energy No options blink with this button s operations From Off Mode Energy button does nothing because the system is off at maximum energy savings already From Auto Mode Both Heat and cool set points back off as specified Default b...

Страница 8: ...each sensor option Up Down arrows cycle through the available options Go to the next Program step by o Pressing Program again o Press the Set button o NOTE Both accepts current setting Exit Time Sensor setup by o Time out 30 seconds o Pressing any button other than Up Down Set or Date Time 1st press of Time Sensor Selects day setting Up Down cycles between each day of the week 2nd press of Time Se...

Страница 9: ...p the various pre programmed modes Wake Leave Return and Sleep Go to the next Program step by o Pressing Program again o Press the Set button o NOTE Both accepts current setting Exit Program setup by o Time out 30 seconds o Pressing any button other than Up Down Set or Program 1st press of Program Selects from available pre program modes Up Down cycles through Wake Leave Return and Sleep NOTE Ener...

Страница 10: ... Down cycles faster NOTE AM PM changes automatically as needed 4th press of Program Selects Cool set point Up Down cycles through temperature 5th press of Program Selects Heat set point Up Down cycles through temperature 6th press of Program Starts the process all over again to program another Mode Day Up Down cycles through time in 15 minute increments Press and hold of Up Down cycles faster NOTE...

Страница 11: ...ld button operations The Hold button over rides a pre programmed mode until either o The mode temp is changed manually by user Including on a remote thermostat templinc o Hold is turned off NOTE If the next pre programmed time comes it will be ignored unless one of the above items occurs NOTE While hold is enabled the pre programmed time notations are not shown NOTE There are no blinking items whe...

Страница 12: ...ation 1st press Makes the local TempLinc the master Before pressing Master button Notice that remote sensor 2 is currently the Master After pressing Master button Notice that remote sensor 2 is no longer the Master The local temp now is Master controlling temperature ...

Страница 13: ...ff power to the Heating Air Conditioning system at the main fuse panel Most residential system have a separate breaker for disconnecting power to the furnace 4 Remove the cover of the old thermostat If it does not come off easily check to see if it is mounted with screws 5 Loosen the screws holding the thermostat base or subbase to the wall and lift away 6 Disconnect the wires from the old thermos...

Страница 14: ...m temperature The air conditioner should turn on NOTE Most equipment has a time delay of 5 minutes between cool cycles 4 Press the UP button until the setpoint is equal to the room temperature Press the FAN button to Fan On The fan should turn on and run continuously Adding a Wireless Thermostat The TempLinc can be paired with a wireless thermostat TempLinc Wireless Zone Thermostat to provide a po...

Страница 15: ...Thermostat will Beep 7 Linking complete with a Beep Beep LED off Linking to Off 1 Set thermostat to desired state 2 Put controller in linking 3 Simultaneously Press hold Thermostat Set button and Down arrow Thermostat Set LED goes GREEN for xx seconds Thermostat will Beep TempLinc will Beep Beep LED off Display while in Linking to On or Off Linking as a Controller TempLinc can be setup to control ...

Страница 16: ... be matched When it is not linked to a TempLinc the set points are local only Wireless TempLinc will send group commands based on local temp and the setpoint shown on the display regardless of whether it s connected to a TempLinc or not Linking Process 1 Press hold Thermostat Set button until it beeps Thermostat Set LED blinks GREEN Thermostat will Beep 2 Press Up arrow to link to Group 1 Cooling ...

Страница 17: ... Beep as a responder 2 Press hold Thermostat Set button to put it in unlinking Thermostat Set LED blinks RED Thermostat will Beep LCD display indicates the group that you are unlinking from 3 Press Up arrow to unlink from Group 1 Cooling mode changes Down arrow to unlink from Group 2 Heating mode changes 4 Press and hold responder Set button Thermostat will Beep Beep to show completion LED off Upo...

Страница 18: ...mode Seen if press Down arrow Can alternate between these last 2 screens by pressing Up and Down Factory Setup Modes To enter a Factory Setup Mode 1 Press Mode Up and Down buttons simultaneously for 3 seconds to enter all of the Factory Setup Modes below 2 All LCD segments will turn on ...

Страница 19: ...ogramming lock Default is Off Sub mode 3 Button Lock Default is Off Sub mode 4 Temperature format select Default is Fahrenheit 2 Press the Up or Down button to change a setting Sub mode 1 Beep on button press Enable Disable a Up arrow On b Down arrow Off default setting Sub mode 2 Programming lock Enable Disable a Up arrow On b Down arrow Off default setting Sub mode 3 Button Lock disables front b...

Страница 20: ...Page 19 of 22 Rev 9 30 2011 1 26 PM Sub mode 4 Termperature format select C or F a Up arrow C b Down arrow F default setting ...

Страница 21: ...y Reset to Default Factory Reset Changes INSTEON is reset all links removed Day time is changed to 12 00 Monday Programming times and temperatures are reset to their default Factory Reset Does Not Change Temperature offset Humidity Offset F or C setting Option 1 1 Remove power press and hold Set button while powering up 2 Continue pressing and holding for 10 seconds Device will blink all segments ...

Страница 22: ...nks RED Thermostat will Beep LCD display indicates the group that you are unlinking from 1 Double tap the Set button 2 Press and hold the set button for 10 seconds 3 Continue pressing and holding for 10 seconds Device will blink all segments and do continuous Beep during 10 seconds 4 When blinking buzzing stops release Set button Device goes into factory reset for 10 seconds Screen goes blank LEDs...

Страница 23: ... product in this Owner s Manual This warranty shall not apply to defects or errors caused by misuse or neglect If the product is found to be defective in material or workmanship or if the product does not perform as warranted above during the warranty period Seller will either repair it replace it or refund the purchase price at its option upon receipt of the product at the address below postage p...

Отзывы: