What’s in the Box? 

In-LineLinc 

Four (4) wire nuts  

Quick-Start Guide  

Installation 

CAUTIONS AND WARNINGS

 

Read and understand these instructions before installing and retain them for future reference. 

In-LineLinc is intended for installation in accordance with the National Electric Code and local regulations in the United States or the 

Canadian Electrical Code and local regulations in Canada. Use indoors only. In-LineLinc is not designed nor approved for use on 

power lines other than 120VAC-277VAC 60Hz. Attempting to use In-LineLinc on non-approved power lines may have hazardous 

consequences. 

 

Use only indoors or in outdoor rated box  

 

Be sure that you have turned off the circuit breaker or removed the fuse for the circuit you are installing In-LineLinc in. 
Installing In-LineLinc with the power on will expose you to dangerous voltages. 

 

Connect only copper or copper-clad wire to In-LineLinc 

 

In-LineLinc may feel warm during operation. The amount of heat generated is within approved limits and poses no 
hazards. To minimize heat buildup, ensure that the area surrounding the rear of In-LineLinc is as clear of clutter as 
possible. 

 

Each In-LineLinc is assigned a unique INSTEON ID, which is printed on the device’s label.  

 

To reduce the risk of overheating and possible damage to other equipment, use In-LineLinc to control no more than 20 
Amps (1800 Watts of incandescent) at 110VAC-277VAC.  

 

You will need a flathead screwdriver, a philips head screwdriver and a voltage meter to install In-LineLinc  

Identifying the Electrical Wires in your Home 

To install In-LineLinc, you will need to identify the following four wires: 

 

LINE - usually black, may also be called HOT or LIVE, carries 110-277VAC electricity to the load  

 

NEUTRAL - usually white 

 

GROUND - bare copper wire or metal fixture (if grounded) 

If you are having difficulties identifying wires, consult an electrician to help you. 

 IMPORTANT!

 

If you are not knowledgeable about, and comfortable with, electrical circuitry, you should have a qualified electrician install In-
LineLinc for you. If you have any questions, please consult an electrician or call: 800-762-7845 

 

Tools You Will Need 

  Screwdrivers (both Flathead and Phillips)  

  Voltage tester  

  Wire cutter / stripper 

  Probe that is non-conductive to press the Set button 

Installing In-LineLinc 

1)  Be sure to write down the INSTEON ID and location of the fixture you’ll be controlling (e.g., 01.F7.G5, 

Mike’s bedroom light)  

                                                                                                                               Page 4 of 12                                                                       2475SDB - Rev: 10/24/2011 3:17 PM 

 

Содержание 2475SDB

Страница 1: ...In LineLinc Relay Owners Manual INSTEON In LineLinc On Off Dual Band 2475SDB Page 1 of 12 2475SDB Rev 10 24 2011 3 17 PM...

Страница 2: ...tes they were at when the scene was programmed 6 Adding In LineLinc to a Scene as a Responder 6 Removing In LineLinc from a Scene as a Responder 6 Advanced Features 6 Using In LineLinc as a Phase Brid...

Страница 3: ...energy saving wireless controller for commercial building automation systems Off button On button LED Set button Features Benefits Once installed setup is easy links to other INSTEON devices in minut...

Страница 4: ...possible Each In LineLinc is assigned a unique INSTEON ID which is printed on the device s label To reduce the risk of overheating and possible damage to other equipment use In LineLinc to control no...

Страница 5: ...e junction box before connecting them Wiring Diagram NOTE Home s wire color and wire location may vary 6 After you have connected all the wires ensure that the wire connectors are firmly attached and...

Страница 6: ...uccessful by tapping On then Off on the controller s scene button The In LineLinc will respond appropriately Removing In LineLinc from a Scene as a Responder If you are going to discontinue using In L...

Страница 7: ...s Set Button In LineLinc will stop beeping and LED returns to previous state Other devices LEDs will stop blinking Restoring Power to In LineLinc In LineLinc stores all of its settings such as links...

Страница 8: ...long beep stops In LineLinc s LED will turn off In LineLinc will emit a long Beep Option 2 two people required 1 If possible remove all scene memberships prior to performing the factory reset 2 Turn c...

Страница 9: ...Off Software Configurable Yes Always RF Range 150 Open air X10 Support Yes X10 Addresses 1 max unassigned by default INSTEON Device Category 0x02 INSTEON Device Subcategory 0x1F INSTEON Product Key I...

Страница 10: ...se Solution Make sure the circuit breaker is turned on The Status LED on In LineLinc is not turning on and won t control the load In LineLinc may not be getting power Check the junction box wires to e...

Страница 11: ...set See Resetting In LineLinc to its Factory Default Settings If you have tried these solutions reviewed this Installation and Programming Guide and still cannot resolve an issue you are having with I...

Страница 12: ...e product at the address below postage prepaid with proof of the date of purchase and an explanation of the defect or error The repair replacement or refund that is provided for above shall be the ful...

Отзывы: