Page 7 of 12 2475SDB - Rev: 10/24/2011 3:17 PM
1)
Start Phase Bridging Detection Mode by tapping the Set button on In-LineLinc four times quickly
In-LineLinc will begin
(Beeping)
Other dual-band devices' LEDs will illuminate at 100% brightness
2)
Check the LED behavior of the “other” dual-band devices
-
If the “other” dual-band device is blinking green
4
i.
it is within range and not on the same phase, proceed to next Step
-
If they are not blinking green
5
i.
Try moving the “other” device, check other dual-band devices or begin
test from a different initiator
3)
Tap In-LineLinc’s Set Button
In-LineLinc will stop beeping and LED returns to previous state
Other devices’ LEDs will stop blinking
Restoring Power to In-LineLinc
In-LineLinc stores all of its settings, such as links to other INSTEON devices, with non-volatile memory.
Because settings are saved in this non-volatile memory, they will not be lost in the event of a power
failure.
In the event of a power loss In-LineLinc will automatically return the load to the state it had before power
was interrupted.
4
Or is simply blinking for single colored LEDs. If the “other” dual-band device is a KeypadLinc Dual-Band, the 4 middle LEDs will blink.
5
Or are not blinking at all for single colored LEDs. If the “other” dual-band device is a KeypadLinc, any LEDs that are on will go to full bright.