![Inspur NF5180M6 Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/inspur/nf5180m6/nf5180m6_user-manual_2069390017.webp)
9
438 × 43.05 × 780 mm (17.24 × 1.69 × 30.71
in.)
32-E1.S SSD system: 438 × 43.05 × 840 mm
(17.24 × 1.69 × 33.07 in.)
Product Weight
4 × 3.5-inch configuration (rear 2.5-inch
drives included):
Net weight: about 21 kg (56.26 lbs)
Gross weight: 31.5 kg (84.40 lbs) (Packages
+Rails + Accessory Box included)
10 × 2.5-inch Configuration (rear 2.5-
inch drives included):
Net weight: about 21 kg (56.26 lbs)
Gross weight: 31 kg (83.06 lbs) (Packages
+Rails + Accessory Box included)
2.3
Power Efficiency
Table 2-2 Platinum Power Supplies
Rated
Power
@20%Load
@50%Load
@100%Load
PF@50%Load
550 W
90%
94%
91%
0.98
800 W
90%
94%
91%
0.98
1300 W
90%
94%
91%
0.98
Table 2-3 Titanium Power Supplies
Rated
Power
@10%
Load
@20%
Load
@50%
Load
@100%
Load
PF@50%
Load
800 W
90%
94%
96%
91%
0.98
Table 2-4 ErP lot 9-1
EU Regulation 2019/424
Server configurations
High-end
performance
configuration
Low-end
performance
configuration
(h) idle state power
322.7W
202.3W
(i) list of all components for
additional idle power allowances,
if any (additional PSU, HDDs or
SSDs, additional memory,
additional buffered DDR channels,
additional I/O devices);
See
See
Содержание NF5180M6
Страница 1: ...Inspur Server NF5180M6 User Manual Document Version V1 5 Release Date February 10 2022 ...
Страница 40: ...32 Figure 4 10 Fan Module Direction Figure 4 11 Installing the Fan Module 3 Install the access panel ...
Страница 103: ...95 USB Universal Serial Bus V VGA Video Graphics Array VLAN Virtual Local Area Network X XDP eXtend Debug Port ...