10
EU Regulation 2019/424
Server configurations
High-end
performance
configuration
Low-end
performance
configuration
(j) maximum power, expressed in
Watts and rounded to the first
decimal place;
956.8 W
688.1 W
(k) declared operating condition
class, as detailed in Table 6;
A2
A2
(l) idle state power (Watts) at the
higher boundary temperature of
the declared operating condition
class;
328.4 W
206.9 W
(m) the active state efficiency and
the performance in active state of
the server;
40.5
30.4
Table 2-5 ErP lot 9-2
(i) List of components for additional
power allowance
High-end
performance
configuration
Low-end
performance
configuration
CPU
Performance
1 socket: 10 × Perf CPU
W
2 socket: 7 × Perf CPU
W
240.31 W
124.81 W
Additional PSU
10 W per PSU
10 W
10 W
HDD or SSD
5,0 W per HDD or SSD
10 W
10 W
Additional
memory
0,18 W per GB
367.92 W
45.36 W
Additional
buffered DDR
channel
4,0 W per buffered
DDR channel
32 W
32 W
Additional I/O
devices
< 1 Gb/s: No
Allowance
= 1 Gb/s: 2,0 W/Active
Port
> 1 Gb/s and < 10
Gb/s: 4,0 W/Active
Port
≥ 10 Gb/s and <
25Gb/s: 15,0 W/Active
Port
0
0
Содержание NF5180M6
Страница 1: ...Inspur Server NF5180M6 User Manual Document Version V1 5 Release Date February 10 2022 ...
Страница 40: ...32 Figure 4 10 Fan Module Direction Figure 4 11 Installing the Fan Module 3 Install the access panel ...
Страница 103: ...95 USB Universal Serial Bus V VGA Video Graphics Array VLAN Virtual Local Area Network X XDP eXtend Debug Port ...