46
3.
Close the M.2 snap clip to secure the M.2 drive in place.
Figure 4-36 Closing the Snap Clip
4.4.10
Hot-Swap and Redundant PSU Replacement
To reduce the risk of personal injury from hot surfaces, allow the power supply
or power supply blank to cool before touching.
To prevent improper cooling and thermal damage, do not operate the server
unless all bays are populated with either a component or a blank.
To remove the PSU:
1.
Grasp the handle, and press the blue release tab to release the PSU.
2.
Pull the PSU out of the power bay and put it into an antistatic bag.
Figure 4-37 Removing the PSU
To install the PSU: