73
8.3
Altitude and Air Pressure
Table 8-3 Altitude and Air Pressure
Parameter
Condition
Requirement
Altitude
Operating
0 to 3,048 m (0 to 10,000 feet)
Transportation
(Storage)
0 to 12,192 m (0 to 40,000 feet)
8.4
Alternating Temperature and Humidity
Table 8-4 Alternating Temperature and Humidity
Parameter
Condition
Requirement
Humidity
Operating
Relative humidity is 5% to 90% with
maximum dew point at 38°C (100.4°F)
Transportation
(Storage)
Relative humidity is 5% to 93% with
maximum dew point at 39°C (102.2°F),
and the air must be non-condensing
all the time
8.5
Expanded Operation Temperature
The system performance will be impacted when the temperature is not
within the specification range;
Ignore alarm sound of ambient temperature when the temperature is not
within the specification range.
Table 8-5 Expanded Operation Temperature
Temperature Specification
Note
5
℃
- 40
℃
(5% - 85%RH)
1
Continuous running is possible
-5
℃
- 45
℃
(5% - 90%RH)
2
Running time
≤
1% per year
8.6
Expanded Operation Temperature Limits
Powering on under 5
℃
is not allowed
The altitude cannot be higher than 3,000 m (9,843 feet)
CPU higher than 165 W is not supported