Chapter 6 Description of Function Codes
- 69 -
Figure 6-7 Door close hindered judgment
Running
frequency (Hz)
Hinder torque
(%)
F4-18
F4-17
F4-20
F4-19
V2
V1
T2
T1
Curve 1
1. According to the preceding figure, set these parameters according to the requirement:
V1 (F4-17) ≥ V2 (F4-18), T1 (F4-19) ≤ T2 (F4-20)
2. The torque threshold for judging door close hindered is curve 1 shown in the figure. The
shadow part shows that door close hindered occurs.
Group F5: Door Open/Close Auxiliary Parameters
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F5-00
Abnormality deceleration time
0.1–5.0s
0.3s
0.1s
It is used to set the time for the system to decelerate from the door close speed to zero speed
when door close is hindered. Set this parameter to the minimum value as possible when
ensuring that overcurrent does not occur during deceleration.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F5-01
Door open time limit
0–999.9s
30.0s
1s
It is used to limit the door open time. If the controller does not receive the door open limit signal
(pulse loss occurs in distance control mode) within the time, it performs door open timeout
protection (Er28).
This parameter is invalid when it is set to 0.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F5-02
Door close time limit
0–999.9s
0s
1s
It is used to limit the door close time. If the controller does not receive the door close limit
signal within the time, it determines that door close is hindered, and performs door re-open or
zero speed holding based on the setting of F4-14.
This parameter is invalid when it is set to 0.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F5-03
Low speed running time limit
0–999.9s
0s
1s
Содержание NICE-D-A-S0P2
Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...
Страница 6: ...1 Safety Information and Precautions...
Страница 12: ...2 Product Information...
Страница 16: ...3 Mechanical and Electrical Installation...
Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Страница 24: ...4 Operation and Trial Running...
Страница 41: ...Chapter 4 Operation and Trial Running 40...
Страница 42: ...5 Function Code Table...
Страница 54: ...6 Description of Function Codes...
Страница 89: ...Chapter 6 Description of Function Codes 88...
Страница 90: ...7 Maintenance and Troubleshooting...