Chapter 4 Operation and Trial Running
- 28 -
4.3 Command Source and Motor Auto-tuning
4.3.1 Command Source
The NICE900 supports four command sources, as described in the following table.
Function
Code
Value
Description
F0-02
0
(Default)
Operation panel control
It is mainly used in motor auto-tuning. The door machine runs at the
frequency set in F0-04.
You can control door open or close by pressing
OPEN
or
CLOSE
, and stop the
door machine by pressing
STOP
RES
on the operation panel.
1
Door machine terminal control
Door open and close commands are input via DI terminal.
It is used in normal running state.
2
Door machine manual control
It is used in door width auto-tuning, during which the door machine
accelerates and decelerates.
The running and stop of the door machine are controlled by using the
operation panel.
3
Door machine auto demonstration
It is used in the door machine demonstration and trial running in the factory.
After door width auto-tuning is completed in distance control or peripheral
signals are connected properly in speed control, set the door machine auto
demonstration mode to start automatic running of the door machine.
Start demonstration by pressing
OPEN
or
CLOSE
, and stop demonstration by
pressing
STOP
RES
on the operation panel.
The demonstration time interval and times are set in group F7 parameters.
Содержание NICE-D-A-S0P2
Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...
Страница 6: ...1 Safety Information and Precautions...
Страница 12: ...2 Product Information...
Страница 16: ...3 Mechanical and Electrical Installation...
Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Страница 24: ...4 Operation and Trial Running...
Страница 41: ...Chapter 4 Operation and Trial Running 40...
Страница 42: ...5 Function Code Table...
Страница 54: ...6 Description of Function Codes...
Страница 89: ...Chapter 6 Description of Function Codes 88...
Страница 90: ...7 Maintenance and Troubleshooting...