Chapter 6 Description of Function Codes
- 64 -
2. When the door open position reaches (F6-04 x door width), the door machine accelerates
to the speed set in F3-03 within the acceleration time set in F3-04.
3. When the door open position reaches (F6-05 x door width), the door machine decelerates
to creep, with the speed =set in F3-05 and deceleration time set in F3-06.
4. When the door open position reaches (F6-06 x door width), the door machine continues
low speed creeping, and then enters the door open holding state, with the holding torque
set in F3-08. The door position is reset to 100%.
5. After the command is cancelled, the torque holding state ends. If torque holding needs to
continue, increase the delay time set in F5-04.
6. The dotted line part in the figure indicates the running curve when F5-06 (Door open
curve) = 0 (Linear acceleration/deceleration).
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F3-07
Torque switchover threshold at
door open limit
0.0%–150.0%
50.0%
0.1%
It is valid only in distance control. After the door reaches the set door open limit position, if the
output torque is greater than F3-07, the door controller resets the width pulses to 100% and
enters the door open limit torque holding state.
If the output torque is not greater than F3-07 after locked-rotor occurs, decrease F3-07 slightly
to smaller than the output torque), ensuring that the door width pulses can be reset.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F3-08
Door open limit holding torque
0.0%–150.0%
50.0%
0.1%
It is used to set the holding torque after the door open limit position is reached.
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F3-09
Door open hindered torque
0.0%–150.0%
80.0%
0.1%
It is used to set the door open hindered torque during door open.
Upper limit of door open torque = F3-09 + 10.0%
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F3-10
Door open startup torque
0.0% to F3-09
0.0%
0.1%
It is used to set the torque at startup of door open to ensure the good startup result of the door
machine.
Actual startup torque = F3-10 x Rated motor torque
Function Code
Parameter Name
Setting Range
Default
Min. Unit
F3-11
Door open hindered judging time
0–9999 ms
0 ms
1 ms
It is used to set the filter time when the door open is hindered. If it is set to 0, door open
hindered is not detected.
Содержание NICE-D-A-S0P2
Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...
Страница 6: ...1 Safety Information and Precautions...
Страница 12: ...2 Product Information...
Страница 16: ...3 Mechanical and Electrical Installation...
Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Страница 24: ...4 Operation and Trial Running...
Страница 41: ...Chapter 4 Operation and Trial Running 40...
Страница 42: ...5 Function Code Table...
Страница 54: ...6 Description of Function Codes...
Страница 89: ...Chapter 6 Description of Function Codes 88...
Страница 90: ...7 Maintenance and Troubleshooting...