  Chapter  5  Function  Code  Table            

- 51 -

Function 

Code

Parameter Name

Setting Range

Default

Min. 

Unit Property

Group FA: Display and Fault Parameters

FA-00 Display in running state

1–511

319

1

FA-01 Display in stop state

1–63

39

1

FA-02 1st fault type

0–30

0

1

FA-03 1st fault prompt

0–9

0

1

FA-04 2nd fault type

0–30

0

1

FA-05 2nd fault prompt

0–9

0

1

FA-06 3rd fault type

0–30

0

1

FA-07 3rd fault prompt

0–9

0

1

FA-08 4th fault type

0–30

0

1

FA-09 4th fault prompt

0–9

0

1

FA-10 5th fault type

0–30

0

1

FA-11 5th fault prompt

0–9

0

1

FA-12 Bus voltage upon latest fault 0–999.9 V

0 V

0.1 V

FA-13 Output current upon latest 

fault

0–99.00 A

0.00 A

0.01 A

FA-14 Running frequency upon 

latest fault

0–99.00 Hz

0.00 Hz

0.01 

Hz

FA-15 Output torque upon latest 

fault

0.0–180.0% (percentage 

of output torque to rated 

torque)

0.0%

0.1%

FA-16 Input terminal status upon 

latest fault

0–1023

0

1

FA-17 Output terminal status upon 

latest fault

0–15

0

1

FA-18 Terminal state display

*

*

*

FA-19 Input signal display

*

*

*

FA-20 Output signal display

*

*

*

FA-21 Parameter display selection 0–9999

0

1

FA-22 Display 1

0–9999

0

1

FA-23 Display 2

0–9999

0

1

FA-24 Analog voltage display

0.00–10.10 V

0.00 V

0.01 V

FA-25 Low bit of current door 

position

0–9999

0

1

FA-26 High bit of current door 

position

0–9999

0

1

FA-27 Door machine state display

0–9999

0

1

FA-28 Door direction judgment

*

*

*

Содержание NICE-D-A-S0P2

Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...

Страница 2: ...describes correct use of the NICE900 including product features safety information and precautions installation parameter setting commissioning and troubleshooting Read and understand the manual befo...

Страница 3: ...in combination with this drive must also be CE certified and marked The integrator who integrates the drive with the CE mark into other devices has the responsibility of ensuring compliance with CE s...

Страница 4: ...ation and Trial Running 24 4 1 Operation Panel 24 4 2 Basic Operations 25 4 3 Command Source and Motor Auto tuning 28 4 4 Door Open Close Control Mode 31 Chapter 5 Function Code Table 42 5 1 Descripti...

Страница 5: ...t and Output Function Parameters 79 Group FA Display and Fault Parameters 81 Group FP User Parameters 87 Chapter 7 Maintenance and Troubleshooting 90 7 1 Maintenance 90 7 2 Fault Information and Troub...

Страница 6: ...1 Safety Information and Precautions...

Страница 7: ...formation Before Installation DANGER Do not install the equipment if you find the controller damaged upon unpacking Do not install the equipment if the packing list does not conform to the product you...

Страница 8: ...e that the shield is reliably grounded at one end Use a twisted cable with twisted distance of 20 30 mm as the communication cable and ensure that the shield is reliably grounded Before Power On DANGE...

Страница 9: ...burnt Signal detection must be performed only by qualified personnel during operation Failure to comply will result in personal injury or damage to the controller CAUTION Avoid objects falling into th...

Страница 10: ...tning protection voltage sensitive resistor on the output side of the controller Otherwise the controller may suffer transient overcurrent or even be damaged 4 Use outside the rated voltage The contro...

Страница 11: ...relcage asynchronous induction motor and AC PMSM Select the proper controller model according to the motor ratings To reach better control result perform motor auto tuning based on actual conditions F...

Страница 12: ...2 Product Information...

Страница 13: ...Technology Co Ltd Serial No 010150144C700061 Nameplate Model Rated input Rated output Serial No INT Version Mark a Other variants INT International Note a The model number may include a suffix XXXXXXX...

Страница 14: ...equency resolution 0 01 Hz Current resolution 0 01 A Carrier frequency 2 16 kHz Major functions Two auto tuning modes are supported with load auto tuning and no load auto tuning For CLVC on the AC PMS...

Страница 15: ...10 C to 40 C Derated if ambient temperature is within 45 50 C Humidity Less than 95 RH non condensing Vibration 5 9 m s2 0 6 g Storage temperature 20 C to 60 C Cooling method Natural cooling for 0 2...

Страница 16: ...3 Mechanical and Electrical Installation...

Страница 17: ...th screws vertically Mounting location Free from direct sunlight high humidity and condensation Free from corrosive explosive and combustible gas Free from oil dirt dust and metal powder 3 1 2 Physica...

Страница 18: ...n Use 4 M4x15 screws with elastic flat washer with the tightening torque of 1 2 N m during installation a Horizontal installation Figure 3 3 Horizontal installation diagram Fix the four screws b Verti...

Страница 19: ...inals Provide single phase 220 VAC power supply P PB Reserved These terminal are generally reserved but they can be connected with the external regen resistor if required U V W Controller output termi...

Страница 20: ...ment Reserved Encoder and control signal input terminal TA1 TC1 TB1 TA2 TB2 TC2 TA3 TC3 TB3 Door state output terminal 24V PGA PGB PGZ COM DI1 DI2 DI3 DI4 DI5 DI6 DI7 DI8 COM 24V COM Table 3 3 Control...

Страница 21: ...e 0 30 VDC Input impedance 3 3 k Reserved Software burning interface RJ45 Software burning interface Check the peripheral wiring before power on to ensure device and personal safety 1 The wiring is pe...

Страница 22: ...t circuit protection AC input reactor Controller input side Improve the power factor of the input side Eliminate the higher harmonics of the input side effectively Protect the rectifier bridge effecti...

Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...

Страница 24: ...4 Operation and Trial Running...

Страница 25: ...ndicator Meaning of ON at Stop Meaning of ON During Running Speed Control Distance Control D1 DI1 signal active DI1 signal active External door close command D2 DI2 signal active Phase A and B signal...

Страница 26: ...and function code setting value level III as shown in the following figure Figure 4 2 Operation procedure on the operation panel F0 F003 24 00 Select the function code group Select the function code...

Страница 27: ...er and running record parameter Such a function code cannot be modified in the running state and can only be changed at stop 4 2 2 Viewing Fault Information When a fault occurs on the controller the o...

Страница 28: ...ncy reference Input terminal state Shift between parameters displayed in stop state Door position pulse Output terminal state Frequency reference for door open Input terminal state Frequency reference...

Страница 29: ...l It is used in normal running state 2 Door machine manual control It is used in door width auto tuning during which the door machine accelerates and decelerates The running and stop of the door machi...

Страница 30: ...pen Command source Door open command Door close F906 F907 F908 F0 02 1 Control system Door close command 4 3 2 Motor Auto tuning The following part takes the PMSM as an example to describe motor auto...

Страница 31: ...ccurs after you start auto tuning it indicates that the motor running direction is abnormal You need to change the motor wiring or encoder wiring 2 During no load auto tuning the controller executes t...

Страница 32: ...es speed control and distance control In speed control the controller instructs deceleration at slow down point and judge door open close limit based on the door open close limit signal In distance co...

Страница 33: ...l F9 01 13 F9 02 15 F9 03 14 F9 04 12 F9 05 1 F9 06 2 F9 09 2 F9 11 1 X5 Door close limit P24 X3 Door open limit B1 B2 BM Door open output Door close output Output common Input common Function code se...

Страница 34: ...is active the door machine enters the door open holding state with the holding torque set in F3 08 Figure 4 12 Door close running curve in speed control Door close command ON ON ON OFF OFF OFF Door cl...

Страница 35: ...input signal Door open input signal F9 05 1 F9 06 2 F9 09 2 F9 11 1 X5 Door close limit P24 X3 Door open limit B1 B2 BM Door open output Door close output Output common Input common M Door motor Encod...

Страница 36: ...s of the encoder are connected correctly During door width auto tuning the door acting direction changes automatically guarantee personal safety before starting the operation Check that there is no ob...

Страница 37: ...eceleration time set in F3 06 When the door open position reaches F6 06 x door width the door machine continues low speed creeping and then enters the door open holding state with the holding torque s...

Страница 38: ...han the door close hindered torque Door open command active If door close hindered occurs the NICE900 processes this abnormality in two ways decelerate to stop or re open the door selected in F4 14 Th...

Страница 39: ...larger than the door close hindered torque The door close time exceeds the value of F5 02 F4 15 Door close hindered judging time 0 9999 ms It is used to set the filter time when door close is hindere...

Страница 40: ...e time limit 0 9999s It is used to limit the door close time If the controller does not receive the door close limit signal within the time it determines that door close is hindered and performs door...

Страница 41: ...Chapter 4 Operation and Trial Running 40...

Страница 42: ...5 Function Code Table...

Страница 43: ...fault setting of the parameter at factory Unit Indicates the measurement unit of the parameter Property Indicates whether the parameter can be modified including the modification conditions The symbol...

Страница 44: ...1 Closed loop vector control CLVC 1 1 F0 01 Door open close mode selection 0 Speed control 1 Distance control 1 1 F0 02 Command source selection 0 Operation panel control 1 Door machine terminal contr...

Страница 45: ...mH F1 13 Back EMF of PMSM 0 250 Model dependent 1 F1 14 Encoder zero position angle of PMSM 0 0 359 9 Model dependent 0 1 F1 15 Real time angle of PMSM 0 0 359 9 Model dependent 0 1 F1 16 Motor auto...

Страница 46: ...1 999 9s 1 0s 0 1s F3 02 Low speed running time for door open startup in speed control 0 1 999 9s 1 0s 0 1s F3 03 Door open normal speed 0 00 Hz to F1 04 15 00 Hz 0 01 Hz F3 04 Door open acceleration...

Страница 47: ...to F4 03 2 00 Hz 0 01 Hz F4 10 Door vane retraction running time 0 9999 ms 500 ms 1 ms F4 11 Torque switchover threshold at door close limit 0 0 150 0 50 0 0 1 F4 12 Door close limit holding torque 0...

Страница 48: ...celeration time start segment falling segment 90 20 0 0 1 F5 10 Falling segment time of door open deceleration S curve 10 0 80 0 acceleration deceleration time start segment falling segment 90 60 0 0...

Страница 49: ...nce control 80 0 99 0 96 0 0 1 F6 07 Low speed running distance of door close startup in distance control 0 0 30 0 10 0 0 1 F6 08 Door close slow down point in distance control 60 0 90 0 70 0 0 1 F6 0...

Страница 50: ...of door open and close times in demonstration mode 0 9999 0 1 Group F8 Auxiliary Parameters F8 00 Software version 0 00 99 99 1 00 0 01 F8 01 Module temperature 0 100 C 0 C 1 C F8 02 Fault auto reset...

Страница 51: ...l NO NC 16 116 Door lock signal NO NC 0 1 F9 02 DI2 function selection 0 1 F9 03 DI3 function selection 0 1 F9 04 DI4 function selection 0 1 F9 05 DI5 function selection 1 1 F9 06 DI6 function selecti...

Страница 52: ...V 0 V 0 1 V FA 13 Output current upon latest fault 0 99 00 A 0 00 A 0 01 A FA 14 Running frequency upon latest fault 0 99 00 Hz 0 00 Hz 0 01 Hz FA 15 Output torque upon latest fault 0 0 180 0 percenta...

Страница 53: ...Setting Range Default Min Unit Property Group FF Factory Parameters Reserved FF 00 Reserved Group FP Display and Fault Parameters FP 00 User password 0 9999 0 1 FP 01 Parameter update 0 No function 1...

Страница 54: ...6 Description of Function Codes...

Страница 55: ...w down point and judges door open close limit based on signals from the limit switches 1 Distance control In the distance control mode door width pulses must be obtained through auto tuning After rele...

Страница 56: ...rial running without use of the controller Set this mode after you finish commissioning the door machine running curve in operation panel control mode Press OPEN or CLOSE to repeat door open close dem...

Страница 57: ...e Default Min Unit F0 07 Carrier frequency 2 0 16 0 kHz 8 0 kHz 0 1 kHz It is used to adjust the carrier frequency of the controller aiming to reduce motor noise avoid resonance of the mechanical syst...

Страница 58: ...of PMSM 0 0 999 9 mH Model dependent 0 1 mH F1 12 Shaft Q inductance of PMSM 0 0 999 9 mH Model dependent 0 1 mH F1 13 Back EMF of PMSM 0 250 Model dependent 1 F1 14 Encoder zero position angle of PMS...

Страница 59: ...e operation panel restores to the display at stop state F1 16 resumes to 0 automatically The values of F1 16 are described as follows 0 No auto tuning 1 Static auto tuning for asynchronous motor It ap...

Страница 60: ...by no load auto tuning Therefore perform no load auto tuning for PMSM if possible If the door is in the close state press OPEN to start auto tuning If the door is in the completely open state press C...

Страница 61: ...e a faster system response increase the proportional gain and reduce the integral time Be aware that this may lead to system oscillation The recommended adjustment method is as follows If the default...

Страница 62: ...up torque of the motor is insufficient If it is set to 0 0 fixed torque boost is enabled Function Code Parameter Name Setting Range Default Min Unit F2 11 Over excitation gain 0 200 64 1 The over exci...

Страница 63: ...Hz 0 01 Hz F3 01 Door open startup acceleration time 0 1 999 9s 1 0s 0 1s F3 02 Low speed running time for door open startup in speed control 0 1 999 9s 1 0s 0 1s F3 03 Door open normal speed 0 00 Hz...

Страница 64: ...n time set in F3 06 4 After the door open limit signal becomes active the door machine enters door open holding state with the holding torque set in F3 08 5 If the torque is required to keep up increa...

Страница 65: ...sition if the output torque is greater than F3 07 the door controller resets the width pulses to 100 and enters the door open limit torque holding state If the output torque is not greater than F3 07...

Страница 66: ...Range Default Min Unit F4 00 Door close startup low speed 0 00 Hz to F4 03 4 00 Hz 0 01 Hz F4 01 Door close startup acceleration time 0 1 999 9s 1 0s 0 1s F4 02 Low speed running time for door close s...

Страница 67: ...oor close running curve in distance control is shown in the following figure Figure 6 6 Door close running curve in distance control mode Door close command ON ON ON OFF OFF OFF Door close slow down p...

Страница 68: ...8 Low speed running time at door close limit 0 9999 ms 300 ms 1 ms The door machine runs at the low speed set in F4 07 after receiving the door close limit signal When the running time is equal to or...

Страница 69: ...re open Door close hindered means that the output torque is greater than the door close hindered torque during door close Function Code Parameter Name Setting Range Default Min Unit F4 15 Door close...

Страница 70: ...m value as possible when ensuring that overcurrent does not occur during deceleration Function Code Parameter Name Setting Range Default Min Unit F5 01 Door open time limit 0 999 9s 30 0s 1s It is use...

Страница 71: ...t that is the holding time of the door open running state when the door open limit signal is active but the door open command from the terminal becomes inactive If the actual holding time exceeds the...

Страница 72: ...ling segment time of door open deceleration S curve 10 0 80 0 acceleration deceleration time start segment falling segment 90 60 0 0 1 F5 12 Start segment time of door close acceleration S curve 10 0...

Страница 73: ...e of F5 16 If the deviation remains too large for more than the time set in F5 17 the controller reports Er32 and performs protection for too large speed deviation When F5 16 is set to 0 the controlle...

Страница 74: ...Unit F6 04 Low speed running distance of door open startup in distance control 0 0 30 0 10 0 0 1 It records the number of pulses in real time during door open in distance control When the number of pu...

Страница 75: ...lose in distance control When the number of pulses is equal to or less than the value door width x 100 F6 09 the door machine performs related processing of door close limit Function Code Parameter Na...

Страница 76: ...rger than F6 19 the door open limit signal is output At this moment even if the output torque is larger than F3 07 the door position is not restored to 100 The door position is restored to 100 only wh...

Страница 77: ...ord the times of door open and close for demonstration The parameter value is stored automatically at power failure Upon door open close limit after power on again the value is calculated by adding 1...

Страница 78: ...ntinues running after an interval of 2s If this parameter is set to 0 the automatic reset function is disabled and faults must be reset manually If no fault occurs or manual reset is performed within...

Страница 79: ...ed if there is no pulse signal within a certain time 2s 1 Bit4 Door processing when both door open and close commands are active 1 Door close preferred 0 Door open preferred 0 Bit5 In door machine ter...

Страница 80: ...rence and may cause malfunction increase the value of this parameter to enhance the anti interference capability However increase of DI filter time will reduce response of DI terminals Function Code P...

Страница 81: ...tive the controller performs door open limit processing 13 113 Door close limit signal NO NC When this signal is active the controller performs door close limit processing 14 114 Door open slow down s...

Страница 82: ...ler receives the door open limit signal or the counting pulses reach the value for door open limit the door lock signal becomes inactive and the ratio of the hindered torque to the rated torque reache...

Страница 83: ...is as follows If a bit is set to 1 the parameter indicated by this bit is displayed if this bit is set to 0 the parameter is not displayed Convert the sum of binary values of all 9 bits to decimal an...

Страница 84: ...in the running state FA 00 includes 6 binary bits each defining a parameter A total of 6 parameters can be can be displayed during running The 6 binary bits correspond to the running parameters listed...

Страница 85: ...t and is not stored in the fault record Function Code Parameter Name Setting Range Default Min Unit FA 18 Terminal state display It is used to view the states of the corresponding input and output ter...

Страница 86: ...close command active B Light curtain signal active C External reset signal active C Safety edge signal active D Forbid terminal input during door open active D Door open limit signal active E Forbid t...

Страница 87: ...lay 2 0 9999 0 1 FA 21 is used to set the actually displayed content of FA 22 and FA 23 for fault identification and commissioning onsite The meanings of values are as follows Value Displayed Content...

Страница 88: ...yed when you manually pull the door to the close direction it indicates that the AB phase signal wiring is correct Otherwise the AB phase signal is abnormal Group FP User Parameters Function Code Para...

Страница 89: ...Chapter 6 Description of Function Codes 88...

Страница 90: ...7 Maintenance and Troubleshooting...

Страница 91: ...Routine maintenance involves checking Whether abnormal noise exists during motor running Whether the motor vibrates excessively Whether the installation environment of the controller changes Whether t...

Страница 92: ...y in poor quality High ambient temperature Frequent load jumping Electrolytic aging Check whether there is liquid leakage Check whether the safety valve has projected Measure the static capacitance Me...

Страница 93: ...Eliminate external problems such as wiring error 2 Perform motor auto tuning again 3 Reduce the burst load 4 Choose a proper encoder and uses a shielded cable for the encoder Er05 Overvoltage during a...

Страница 94: ...ler decelerates and stops Er14 Module overheat 1 The ambient temperature is too high 2 The fan is damaged 3 The air filter is blocked 1 Reduce the ambient temperature 2 Replace the fan 3 Clear the air...

Страница 95: ...idth auto tuning is smaller than 20 pulses 2 Distance control running is performed before door width auto tuning 1 Check wiring of the encoder and related parameters 2 Check the mechanical system of t...

Страница 96: ...on or deceleration time 2 Perform angle auto tuning again 3 Change the value of F5 16 and F5 17 Er33 Door close limit switch abnormal This signal is not detected during door close when the limit switc...

Страница 97: ...Revision History 96 Revision History Date Version Change Description Jan 2015 V0 0 First issue Dec 2016 A01 Modified product name designation rule and nameplate Nov 2018 A02 Updated logo...

Страница 98: ...ers and secondary disasters c Hardware damage caused by dropping or transportation after procurement d Operations not following the user instructions e Damage out of the equipment for example external...

Страница 99: ...6 512 6285 6720 Service Hotline 400 777 1260 http www inovance com Shenzhen Inovance Technology Co Ltd Add Building E Hongwei Industry Park Liuxian Road Baocheng No 70 Zone Bao an District Shenzhen Te...

Отзывы: