Chapter 6 Description of Function Codes
- 57 -
Function
Code
Parameter Name
Setting Range
Default
Min. Unit
F1-01
Rated motor power
0–750 W
Model dependent
1 W
F1-02
Rated motor voltage
0–250 V
100 V
1 V
F1-03
Rated motor current
0.001–9.900 A
Model dependent
0.001 A
F1-04
Rated motor frequency 1.00–99.00 Hz
24.00 Hz
0.01 Hz
F1-05
Rated motor speed
0–9999 RPM
180 RPM
1 RPM
Set the parameters according to the motor nameplate. Ensure that these motor parameters
are set correctly. Incorrect setting affects the motor auto-tuning and the vector control effect.
Function
Code
Parameter Name
Setting Range
Default
Min. Unit
F1-06
Stator phase resistance of PMSM
0.00–99.99 Ω
Model dependent
0.01 Ω
F1-07
Rotor phase resistance of
asynchronous motor
0.00–99.99 Ω
Model dependent
0.01 Ω
F1-08
Leakage inductance of
asynchronous motor
0.0–99.99 mH
Model dependent
0.01 mH
F1-09
Mutual inductance of asynchronous
motor
0–999.9 mH
Model dependent
0.1 mH
F1-10
Magnetizing current of
asynchronous motor
0.001–9.900 A
Model dependent
0.001 A
F1-11
Shaft D inductance of PMSM
0.0–999.9 mH
Model dependent
0.1 mH
F1-12
Shaft Q inductance of PMSM
0.0–999.9 mH
Model dependent
0.1 mH
F1-13
Back EMF of PMSM
0–250
Model dependent
1
F1-14
Encoder zero position angle of
PMSM
0.0–359.9°
Model dependent
0.1°
F1-15
Real-time angle of PMSM
0.0–359.9°
Model dependent
0.1°
Select a proper motor model according to the adaptable motor power. If there is a great
difference between the actual motor power and the adaptable motor power, the system control
performance will degrade.
F1-06 to F1-14 are updated automatically after motor auto-tuning is completed successfully.
For an asynchronous motor, the NICE900 obtains the corresponding parameters through
complete auto-tuning or static auto-tuning. If the onsite conditions does not allow motor auto-
tuning, manually input the value of these parameters by referring to data of the motor with the
same nameplate parameters.
Each time F1-01(Rated motor power) is changed, the controller automatically resumes
parameters F1-06 to F1-10 to the default values.
For a PMSM, the NICE900 can obtain F1-06 and F1-11 to F1-14 through complete auto-
tuning. After F1-01 is changed, the related parameters will not update.
F1-15 is used to display the magnetic pole position of the motor in real time.
Содержание NICE-D-A-S0P2
Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...
Страница 6: ...1 Safety Information and Precautions...
Страница 12: ...2 Product Information...
Страница 16: ...3 Mechanical and Electrical Installation...
Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Страница 24: ...4 Operation and Trial Running...
Страница 41: ...Chapter 4 Operation and Trial Running 40...
Страница 42: ...5 Function Code Table...
Страница 54: ...6 Description of Function Codes...
Страница 89: ...Chapter 6 Description of Function Codes 88...
Страница 90: ...7 Maintenance and Troubleshooting...