Chapter 6 Description of Function Codes
- 81 -
During door close, the controller outputs this signal after the controller receives the door
close limit signal or the counting pulses reach the value for door close limit.
•
3: Door open limit signal output 1
During door open, the controller outputs this signal after the controller receives the door
open limit signal or the counting pulses reach the value for door open limit, and the
hindered torque reaches the value set in F3-07.
•
4: Door close limit signal output 1
During door close, the controller outputs this signal after the controller receives the door
close limit signal or the counting pulses reach the value for door close limit, and the ratio of
the hindered torque to the rated torque reaches the value set in F4-11.
•
5: Fault signal output 1
Er26 is only a prompt rather than a fault.
•
6: Reserved
•
7: Door open limit signal output 2
During door open, the controller outputs this signal after the controller receives the door
open limit signal or the counting pulses reach the value for door open limit, the door lock
signal becomes inactive, and the ratio of the hindered torque to the rated torque reaches
the value set in F3-07.
•
8: Door close limit signal output 2
During door close, the controller outputs this signal after the controller receives the door
close limit signal or the counting pulses reach the value at door close limit, the door lock
signal becomes inactive, and the ratio of the hindered torque to the rated torque reaches
the value set in F4-11.
•
9: Door lock signal output
It is simultaneous with the door lock signal input.
•
10: Door re-open signal output
This signal is output during door re-open.
•
11: Hindering signal output
This signal is output when door close is hindered.
•
12: Door position feedback output
When the door width position is greater than F6-21, the door position feedback signal is
output.
Group FA: Display and Fault Parameters
Function Code
Parameter Name
Setting Range
Default
Min. Unit
FA-00
Display in running state
1–511
319
1
It is used to set the parameters displayed on the operation panel when the door machine is in
Содержание NICE-D-A-S0P2
Страница 1: ...User Guide NICE900 Series Integrated Door Operator Controller A02 Data code 19010269 User Guide...
Страница 6: ...1 Safety Information and Precautions...
Страница 12: ...2 Product Information...
Страница 16: ...3 Mechanical and Electrical Installation...
Страница 23: ...Chapter 3 Mechanical and Electrical Installation 22...
Страница 24: ...4 Operation and Trial Running...
Страница 41: ...Chapter 4 Operation and Trial Running 40...
Страница 42: ...5 Function Code Table...
Страница 54: ...6 Description of Function Codes...
Страница 89: ...Chapter 6 Description of Function Codes 88...
Страница 90: ...7 Maintenance and Troubleshooting...