Description of Function Codes
MD380 User Manual
- 234 -
*URXS$&RQWURO2SWLPL]DWLRQ3DUDPHWHUV
Function Code
Parameter Name
Setting Range
Default
A5-00
'3:0VZLWFKRYHUIUHTXHQF\XSSHUOLPLW
0.00–15.00 Hz
12.00 Hz
This parameter is valid only for V/F control.
It is used to determine the wave modulation mode in V/F control of asynchronous motor.
If the frequency is lower than the value of this parameter, the waveform is 7-segment
continuous modulation. If the frequency is higher than the value of this parameter, the
waveform is 5-segment intermittent modulation.
The 7-segment continuous modulation causes more loss to switches of the AC drive but
smaller current ripple. The 5-segment intermittent modulation causes less loss to switches
of the AC drive but larger current ripple. This may lead to motor running instability at high
frequency. Do not modify this parameter generally.
For instability of V/F control, refer to parameter F3-11. For loss to AC drive and temperature
rise, refer to parameter F0-15.
Function Code
Parameter Name
Setting Range
Default
A5-01
3:0PRGXODWLRQPRGH
0: Asynchronous modulation
1: Synchronous modulation
0
This parameter is valid only for V/F control.
Synchronous modulation indicates that the carrier frequency varies linearly with the change
of the output frequency, ensuring that the ratio of carrier frequency to output frequency
remains unchanged. Synchronous modulation is generally used at high output frequency,
which helps improve the output voltage quality.
At low output frequency (100 Hz or lower), synchronous modulation is not required. This is
because asynchronous modulation is preferred when the ratio of carrier frequency to output
frequency is high.
Synchronous modulation takes effect only when the running frequency is higher than 85 Hz.
If the frequency is lower than 85 Hz, asynchronous modulation is always used.
Function Code
Parameter Name
Setting Range
Default
A5-02
Dead zone compensation
mode selection
0: No compensation
1: Compensation mode 1
1
Generally, you need not modify this parameter. Try to use a different compensation mode
only when there is special requirement on the output voltage waveform quality or oscillation
occurs on the motor.
Function Code
Parameter Name
Setting Range
Default
A5-03
5DQGRP3:0GHSWK
5DQGRP3:0LQYDOLG
1–10
0
7KHVHWWLQJRIUDQGRP3:0GHSWKFDQPDNHWKHVKULOOPRWRUQRLVHVRIWHUDQGUHGXFHWKH
HOHFWURPDJQHWLFLQWHUIHUHQFH,IWKLVSDUDPHWHULVVHWWRUDQGRP3:0LVLQYDOLG
efesotomasyon.com
Содержание MD380 Series
Страница 8: ...efesotomasyon com...
Страница 9: ...1 Safety Information and Precautions efesotomasyon com...
Страница 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Страница 17: ...2 Product Information efesotomasyon com...
Страница 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Страница 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Страница 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Страница 47: ...4 Operation Display and Application Examples efesotomasyon com...
Страница 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Страница 83: ...5 Function Code Table efesotomasyon com...
Страница 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Страница 139: ...6 Description of Function Codes efesotomasyon com...
Страница 249: ...7 EMC efesotomasyon com...
Страница 261: ...8 Selection and Dimensions efesotomasyon com...
Страница 293: ...9 Maintenance and Troubleshooting efesotomasyon com...