Description of Function Codes
MD380 User Manual
- 162 -
Group F4: Input Terminals
7KH0'SURYLGHV¿YH',WHUPLQDOV',FDQEHXVHGIRUKLJKVSHHGSXOVHLQSXWDQGWZR
DQDORJLQSXW$,WHUPLQDOV7KHRSWLRQDOH[WHQVLRQFDUGSURYLGHVDQRWKHU¿YH',WHUPLQDOV
(DI6 to DI10) and an AI terminal (AI3).
Function Code
Parameter Name
Default
Remark
F4-00
DI1 function selection
)RUZDUG581):'
Standard
F4-01
DI2 function selection
)RUZDUGMRJ)-2*
Standard
F4-02
DI3 function selection
9: Fault reset (RESET)
Standard
F4-03
DI4 function selection
12: Multi-reference terminal 1
Standard
F4-04
DI5 function selection
13: Multi-reference terminal 2
Standard
F4-05
DI6 function selection
0
Extended
F4-06
DI7 function selection
0
Extended
F4-07
DI8 function selection
0
Extended
F4-08
DI9 function selection
0
Extended
F4-09
DI10 function selection
0
Extended
The following table lists the functions available for the DI terminals.
Table 6-1 Functions of DI terminals
Value
Function
Description
0
No function
Allocate reserved terminals with function 0 to avoid
malfunction.
1
)RUZDUG581):'
The terminal is used to control forward or reverse
running of the AC drive.
2
5HYHUVH5815(9
3
Three-wire control mode
The terminal determines three-wire control mode of the
AC drive. For details, see the description of F4-11.
4
)RUZDUGMRJ)-2*
)-2*LQGLFDWHVIRUZDUGMRJUXQQLQJZKLOH5-2*
indicates reverse jog running. The jog frequency,
acceleration time and deceleration time are described
respectively in F8-00, F8-01 and F8-02.
5
5HYHUVHMRJ5-2*
6
7HUPLQDO83
If the frequency is determined by external terminals, the
terminals with the two functions are used as increment
DQGGHFUHPHQWFRPPDQGVIRUIUHTXHQF\PRGL¿FDWLRQ
:KHQWKHIUHTXHQF\VRXUFHLVGLJLWDOVHWWLQJWKH\DUH
used to adjust the frequency.
7
7HUPLQDO'2:1
8
Coast to stop
The AC drive blocks its output, and the stop process
of the motor is not controlled by the AC drive. It is the
same as coast to stop described in F6-10.
9
Fault reset (RESET)
The terminal is used for fault reset function, the same
as the function of RESET key on the operation panel.
Remote fault reset is implemented by this function.
efesotomasyon.com
Содержание MD380 Series
Страница 8: ...efesotomasyon com...
Страница 9: ...1 Safety Information and Precautions efesotomasyon com...
Страница 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Страница 17: ...2 Product Information efesotomasyon com...
Страница 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Страница 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Страница 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Страница 47: ...4 Operation Display and Application Examples efesotomasyon com...
Страница 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Страница 83: ...5 Function Code Table efesotomasyon com...