MD380 User Manual Desc
ription of Function Codes
- 179 -
Group F6: Start/Stop Control
Function Code
Parameter Name
Setting Range
Default
F6-00
Startup mode
0: Direct startup
1: Catching a spinning motor
2: Pre-excited startup (AC asynchronous
motor)
0
0: Direct startup
–
If the DC injection braking active time is set to 0, the AC drive starts to run at the
startup frequency.
–
If the DC injection braking active time is not 0, the AC drive performs DC injection
braking first and then starts to run at the startup frequency. It is applicable to
small-inertia load application where the motor is likely to rotate at startup.
1: Catching a spinning motor
To catch a spinning motor, the AC drive detects the speed and direction of the spinning
motor, and outputs the voltage corresponding to the motor frequency, minimizing
impact of power supply to the motor.
It is applicable to the restart upon instantaneous power down of large-inertia load. To
ensure the performance of rotational speed tracking restart, set the motor parameters
in group F1 correctly.
2: Pre-excited startup (AC asynchronous motor)
,WLVYDOLGRQO\IRUDV\QFKURQRXVPRWRUDQGXVHGIRUEXLOGLQJWKHPDJQHWLF¿HOGEHIRUH
the motor runs. For pre-excited current and pre-excited time, see parameters of F6-05
and F6-06.
–
If the pre-excited time is 0, the AC drive cancels pre-excitation and starts to run at
startup frequency.
–
If the pre-excited time is not 0, the AC drive pre-excites first before startup,
improving the dynamic response of the motor.
Function Code
Parameter Name
Setting Range
Default
F6-01
Motor of catching a
spinning motor
0: From stop frequency
1: From zero speed
2: From maximum frequency
0
To catch a spinning motor within the shortest time, select a proper catching mode.
0: From stop frequency
It is the commonly selected mode.
1: From zero frequency
It is applicable to restartup after a long time of power failure.
2: From the maximum frequency
It is applicable to the power-generating load.
efesotomasyon.com
Содержание MD380 Series
Страница 8: ...efesotomasyon com...
Страница 9: ...1 Safety Information and Precautions efesotomasyon com...
Страница 16: ...Safety Information and Precautions MD380 User Manual 16 efesotomasyon com...
Страница 17: ...2 Product Information efesotomasyon com...
Страница 28: ...Product Information MD380 User Manual 28 efesotomasyon com...
Страница 29: ...3 Mechanical and Electrical Installation efesotomasyon com...
Страница 46: ...Mechanical and Electrical Installation MD380 User Manual 46 efesotomasyon com...
Страница 47: ...4 Operation Display and Application Examples efesotomasyon com...
Страница 82: ...Operation Display and Application Examples MD380 User Manual 82 efesotomasyon com...
Страница 83: ...5 Function Code Table efesotomasyon com...
Страница 138: ...Function Code Table MD380 User Manual 138 efesotomasyon com...
Страница 139: ...6 Description of Function Codes efesotomasyon com...
Страница 249: ...7 EMC efesotomasyon com...
Страница 261: ...8 Selection and Dimensions efesotomasyon com...
Страница 293: ...9 Maintenance and Troubleshooting efesotomasyon com...