2 Wiring
- 12 -
•
DIP switch setting
Filter Selection
Definition
Address Setting
Value
Frequency Dividing
Coefficient
DIP Switch
8
7
6
5
4
3
2
1
0
0
Non-self-
adaptive filter
0
0
0
0
0
0 Reserved No output
Filter
selection
Frequency dividing
coefficient setting
ON
1
2
3
4
5
6
7
8
DIP
Low bits
High bits
0
0
0
0
0
1 1
Frequency divided by 1
0
1
Self-adaptive
filter
0
0
0
0
1
0 2
Frequency divided by 2
0
0
0
0
1
1 3
Frequency divided by 3
1
0
Fixed inter-
lock
���
1
1
1
1
0
1 61
Frequency divided by 61
1
1
Automatic
inter-lock
1
1
1
1
1
0 62
Frequency divided by 62
1
1
1
1
1
1 63
Frequency divided by 63
•
Indicators
Indicator
Indication
State
Description
D1/D2/D3
Encoder input signal
indicator
ON or flash
The encoder has signal input�
OFF
The encoder does not have signal input�
D6
Power indicator
ON
Normal�
OFF
Power is not connected�
LED1
Encoder input signal
quality indicator
ON
Input signal is slightly instable, which occurs when motor accelerates/
decelerates or encoder signal input suffers slight interference�
OFF
Input signal is normal, speed is stable and there is no interference�
Flash slowly
Input signal is moderately instable, which occurs when motor accelerates/
decelerates or encoder signal input suffers moderate interference�
Flash quickly Input signal is seriously instable, which occurs when motor accelerates/
decelerates quickly or encoder signal input suffers severe interference�
LED2
Signal processing
quality indicator
ON
Signal is slightly instable, which occurs when motor accelerates/decelerates
or interference during signal input is not completely filtered (The number of
interference pulses that are not filtered is less than 10 per time unit).
OFF
Signal processing is normal, speed is stable and there is no interference�
Flash slowly
Signal is moderately instable, which occurs when motor accelerates/
decelerates or interference during signal input is not completely filtered (The
number of interference pulses that are not filtered is less than 30 per time unit).
Flash quickly Signal is seriously instable, which occurs when motor accelerates/decelerates
or interference during signal input is not completely filtered (The number of
interference pulses that are not filtered is more than 30 per time unit).
LED3
Inter-lock state
indicator
ON
Inter-lock enabled�
OFF
Inter-lock disabled�
LED4
System state indicator ON
Normal�
OFF
The system is not operating or abnormal�
Flash
The encoder cable breaks�