5
SETTING A.C. LINE
VOLTAGES
The game comes with 4 available line voltage settings as
described below. These settings should be used to
provide A.C. power in the correct range to the game
without over or under powering it.
POWER RANGE VOLTAGE SETTING
90–110 V.A.C.
110
110–130 V.A.C.
120
200–220 V.A.C.
220
220–240 V.A.C.
240
The game uses a POWER MODULE to handle all of the
A.C. power distribution chores of the game. It incorporates
an On–Off switch, primary A.C. game fusing, and power
switching capabilities. This allows the game to be used
with a wide variety of A.C. voltages by re–strapping the
main transformer.
A.C. LINE VOLTAGE
ADJUSTMENT
To adjust the game for a different A.C. voltage:
•
Unplug the game from the outlet.
•
Disconnect the power cord from the power
module.
•
Using a small flat blade screwdriver, pry the fuse
holder from the power module.
•
Notice a small window on the fuse holder with an
arrow that points to the voltage the game is
presently set at.
•
Using a small flat blade screwdriver, lift the
retaining tab that holds the voltage selector in the
fuse holder.
•
Rotate the voltage selector until the voltage you
want is displayed in the voltage select window.
•
Push the voltage selector back into the fuse holder
until it snaps into place. NOTE: Do not force the
selector into the fuse holder. If it does not go in
easily, it is not being installed correctly.
ASSEMBLY
•
Snap the fuse holder assembly back into the
power module.
•
Plug the power cord back into the receptacle in the
power module, and into the wall outlet.
NOTE: WHEN CHANGING VOLTAGES FROM THE
110–120 TO 220–240 RANGE, LOWER THE MAIN FUSE
AMPERAGE VALUE BY ½.
WHEN CHANGING FROM THE 220–240 TO 110–120
VOLT RANGE, DOUBLE THE MAIN FUSE AMPERAGE
VALUE.