9.C System configuration and installation
An InnovaSON console is delivered with the following basis modules : a controller, MC-64 for the Mix
Box and a mixing and processing module DSP: Sy80, Sy40-8 or DM-Mk9. The audio rack, totally
modular, is configured according to the needs of the user and the application with inputs and outputs,
analogue or digital, to be defined in the mix position.
For a
local
use (without digital Stage Box transmission) the Mix Box will be preferably fitted with
output modules from slots A to x and input modules from x+1 to H. This will facilitate a possible Stage
Box connection without too much changing to stay compatible.
With a Stage Box, you must define :
How many inputs and outputs are used on stage
How many mix positions share the Stage Box (FOH, Monitors, Recording..)
Which console is MASTER of the Stage Box (and has return audio channels to it).
9.C.1 General rule for using the Stage Box
The total amount of inputs between the Stage Box and each Mix Box is 64, if 48 inputs are installed in
the Stage Box, 16 inputs maximum will be possible in each Mix Box. And the Stage Box, connected
to one or several Mix Box(es) must be configured as follows :
The input modules (SI-8D, DI-8S, DI-8Src) must be placed contiguously from the slot A to the next
used slot (for example slot F for 48 stage inputs).
The Stage Box transmits only the contiguous input modules detected from slot A and the data stream
stops when an empty slot or an output module is detected.
So an empty slot or an output module is strictly forbidden in the middle of input modules.
The Stage Box next free slots (G and H) are used for output modules (MO-8D3, DO-8A), or blank
panels according to the use.
Each Mix Box (or Sy40) connected to this Stage Box may be equipped with input modules (SI-8D, DI-
8S, DI-8Src) in the slots that are different of the Stage Box ones fitted with inputs (G and H in this
example).
Sensoft will display a configuration error if a local input module is detected “in front” of a Stage one.
Of course, these slots are usable for output modules (MO-8D, XO-8D2, DO-8A, DO8-X) or blank
panels.
In the following example, illustrated below, the Stage Box, fitted with 48 inputs and 16 outputs, may be
used and connected to Mix Box(es) with their slots A to H empty or equipped with output modules.
Содержание SY40
Страница 2: ......
Страница 12: ......
Страница 16: ...2 4 THE SY80 CONSOLE User Guide InnovaSON January 2005 2 C 1 Dimensions and general information ...
Страница 38: ......
Страница 58: ......
Страница 106: ......
Страница 128: ......
Страница 146: ......
Страница 169: ......
Страница 187: ......
Страница 215: ......
Страница 221: ...TECHNICAL CHARACTERISTICS RACKS AND MODULES 9 15BIS User Guide InnovaSON April 2005 ...
Страница 226: ...TECHNICAL CHARACTERISTICS RACKS AND MODULES 9 19 User Guide InnovaSON January 2004 ...
Страница 243: ...Headquarters Zone du Kenyah F 56400 Plougoumelen FRANCE tel 33 0 297 24 34 34 fax 33 0 297 24 34 30 www innovason com ...