6
GENERAL
1�3 Recipients
User
Non-expert person capable of operating the product in safe
conditions for people, for the product itself and the environ-
ment, interpreting an elementary diagnostic of faults and
abnormal operating conditions, carrying out simple adjust-
ment, checking and maintenance operations.
Installer
Expert person qualified to position and connect (hydraulical-
ly, electrically, etc.) the unit to the plant; this person is respon-
sible for handling and correct installation according to the
instructions provided in this manual and the national stand-
ards currently in force.
To work on the refrigeration circuit, the installer must comply
with the provisions of Regulation 303/2008/EC which defines,
in accordance with Directive 842/2006/EC, the requirements
for companies and personnel with regard to fixed refrigera-
tion, air conditioning and heat pump equipment containing
certain fluorinated greenhouse gases (F-gas licence).
Service
Expert and qualified person authorised directly by the man-
ufacturer to carry out all routine and supplementary mainte-
nance operations, as well as every adjustment, check, repair
and replacement of parts necessary during the life of the unit
itself.
Service personnel must comply with the provisions of Reg-
ulation 303/2008/EC which defines, in accordance with Di-
rective 842/2006/EC, the requirements for companies and
personnel with regard to fixed refrigeration, air conditioning
and heat pump equipment containing certain fluorinated
greenhouse gases (F-gas licence).
1�4 General warnings
This instruction manual forms an integral part of the de-
vice and therefore must be carefully preserved and must
ALWAYS travel with it, even if you transfer the device to an-
other owner or relocate it to other premises. If the manual
gets damaged or lost, download a copy from the website.
Read this manual carefully before proceeding with any
operation and follow the instructions in the individual
chapters.
All personnel involved must be aware of the operations
and dangers that may arise when beginning all unit instal-
lation operations.
Specific warnings are given in each chapter of the docu-
ment and must be read before starting operations.
Installation performed outside the warnings provided in
this manual and use of the appliance outside the pre-
scribed temperature limits will invalidate the warranty.
The installation and maintenance of climate control
equipment could be dangerous because there is pressur-
ised refrigerant gas and live electrical components inside
the appliances. The installation, initial start-up and subse-
quent maintenance phases must be carried out exclusive-
ly by authorised and qualified personnel (see first start-up
request form enclosed with the appliance).
Any contractual or extra-contractual liability for damage
caused to persons, animals or property, due to installation,
adjustment and maintenance errors or improper use is ex-
cluded. All uses not expressly indicated in this manual are
not permitted.
Only qualified installer companies are authorised to in-
stall the device. After having completed installation, the
installer will issue a declaration of conformity to the plant
manager, as required by the applicable standards and the
guidelines provided by contractor's instruction manual
supplied with the device.
First start-up and repair or maintenance operations must
be carried out by the Technical Assistance Centre or by
qualified personnel following the provisions of this man-
ual.
Do not modify or tamper with the appliance as this can
lead to dangerous situations.
Use suitable accident-prevention clothing and equip-
ment during installation and/or maintenance operations.
The manufacturer is not liable for the non-observance of
the current safety and accident prevention regulations.
In the event of liquid or oil leaks, set the master switch of
the plant to "off" and close the water taps. Call the author-
ised Technical Assistance Centre or professionally qualified
personnel as soon as possible and do not work on the ap-
pliance yourself.
In case of replacement of parts, use only original parts.
The manufacturer is not responsible for damages to per-
sons or property caused by failure to follow the instruc-
tions in this manual.
The manufacturer reserves the right to make changes to
its models at any time to improve its product, without
prejudice to the essential characteristics described in
this manual. The manufacturer is not obliged to add such
modifications to machines previously manufactured, al-
ready delivered or under construction.
This document is restricted in use to the terms of the law
and may not be copied or transferred to third parties with-
out the express authorization of the manufacturer.
Specific warnings for R32
This document contains only some of the warnings re-
lated to the refrigerant R32. For more comprehensive in-
formation, carefully read the safety data sheet available
from the dealer.
Each chapter contains specific warnings for the opera-
tions it describes. These warnings must be read before
starting activities.
All precautions concerning the treatment of the refriger-
ant must be observed following the regulations in force.
The unit uses environmentally friendly R32 refrigerant gas,
with a Global Warming Potential (GWP) = 650. Do not re-
lease R32 gas into the atmosphere.
Содержание Stone Monoblock M1
Страница 1: ...EN Monoblock M1 Installer manual...
Страница 46: ...46 Installation Fitting of cosmetic covering elements 3 1 2 2 2 3 1 1...
Страница 48: ...48 Installation Fitting of cosmetic covering elements 1 2 3 1 3 2 2 1...
Страница 70: ...70 NOTE...
Страница 71: ...71 NOTE...