Additional Tests
SYSTEM/ACTUATOR TESTS
42
An “instructional” screen displays. Prepare the vehicle for test as
directed:
- Turn the ignition on. DO NOT start the engine.
2.
Choose
Yes
to continue.
A “status” screen displays while a vehicle status check is
performed.
3.
A “confirmation” screen displays when
the test routine begins.
A “results” screen displays when the
test procedure has completed.
The screen shows the current
values for
APP 1 Volts
,
APP 2
Volts
,
TPS 1 Volts
,
TPS 2 Volts
and
Throttle Blade 1 Position
.
4.
Choose
Exit
to return to the Special
Functions menu.
Pedal Follower Mode
1.
Select
Pedal Follower Mode
in the Special Functions menu, then
press
ENTER
.
An “instructional” screen displays. Prepare the vehicle for test as
directed:
- Turn the ignition on. DO NOT start the engine.
2.
Choose
Yes
to continue.
A “status” screen displays while a vehicle status check is
performed.
3.
A “confirmation” screen displays when
the test routine begins.
A “results” screen displays when the
test procedure has completed.
The screen shows the current
values for
APP 1 Volts
,
APP 2
Volts
,
TPS 1 Volts
,
TPS 2 Volts
and
Throttle Blade 1 Position
.
4.
Choose
Finish
to return to the Special Functions menu.
NVLD Forced Monitor Test Routine Start
The NVLD Forced Monitor Test Routine Start function lets you perform
a Natural Vacuum Leak Detection (NVLD) forced monitor test.
1.
Select
NVLD Forced Monitor Test Routine Start
in the Special
Functions menu, then press
ENTER
.