INNO View 950M Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

Revision 1.0 

Содержание View 950M

Страница 1: ...Revision 1 0...

Страница 2: ...IFICATIONS 10 3 MENU DESCRIPTIONS 12 3 1 MAIN WINDOW DESCRIPTION 13 3 2 MEASURE 16 3 3 STIMULUS 18 3 3 1 STIMULUS CHANGE ORDER 18 3 4 SCALE 19 3 4 1 SCALE CHANGE ORDER 20 3 5 SWEEP 21 3 5 1 EXTERNAL T...

Страница 3: ...2 2 FILE LOAD 36 3 13 SYSTEM 38 3 13 1 LAN SETUP 39 3 13 2 UPGRADE 39 3 13 3 INFORMATION 41 4 TEST METHOD 42 4 1 CALIBRATION PROCEDURE 43 4 1 1 OSL CALIBRATION 44 4 1 2 E CAL CALIBRATION 46 4 2 MULTI...

Страница 4: ...View950M Multi Scan INNO Instrument Inc Page 4 of 55 1 GENERAL INFORMATION...

Страница 5: ...In other words in production lines that want to measure simple VSWRs quickly it is somewhat less competitive to produce using expensive 4 port networks As competition intensified in smart phones produ...

Страница 6: ...View950M Multi Scan INNO Instrument Inc Page 6 of 55 Ext For Jig Supply DC 24V Out Jig Interface 32Pin 19 rack mountable 1 2 THE LAYOUT OF VIEW900 Image 3 types Front photo Rear photo Top photo...

Страница 7: ...View950M Multi Scan INNO Instrument Inc Page 7 of 55...

Страница 8: ...View950M Multi Scan INNO Instrument Inc Page 8 of 55 2 INSTRUMENT OVERVIEW...

Страница 9: ...here are two USB ports and a power button Items Quantity Explanatikon LCD 1 10 4 TFT Color LCD Touch Screen RF Port 4 N Type 50 Female USB 2 Type A USB 2 0 500mA Power Button 1 One push on off Blue LE...

Страница 10: ...c USB 2 Type A USB 2 0 480mA Video Out 1 RGB connector Max 1920 X 1200 60Hz for LCD connection Ethernet 1 Ethernet terminal for external connection 3 pole AC terminal 1 3 pole power terminal for AC in...

Страница 11: ...tion equipped Immunity On Frequency 5dBm On Channel 15dBm General Display 10 4 TFT Color LCD 800 X 600 Touch Screen Memory SSD 32Gbyte Operating System Windows 10 Front Connector USB 2 0 Type A 2 Port...

Страница 12: ...View950M Multi Scan INNO Instrument Inc Page 12 of 55 3 MENU DESCRIPTIONS...

Страница 13: ...screen appears as shown below Log Mag measurement results of 4 ports are displayed by default The screen can be roughly divided into three parts Port Display Setting Full Multi Preset execution Test...

Страница 14: ...con is colored blue the rest gray If the port marked in blue is Active Preset Icon Explanation Single port Preset execution Preset is executed when clicking on the currently set active port Execute al...

Страница 15: ...The yellow box at the top of the picture above shows the following expression Trace indicating area Expression Other expressions Explanation Indicate selected and non selected port Indicate trace 1 a...

Страница 16: ...ale setup menu Enter Sweep setup menu Enter Display setup menu Enter Marker setup menu Enter Calibration setup menu Enter Limit setup menu Enter Trace setup menu Enter Save setup menu Enter Load setup...

Страница 17: ...t Inc Page 17 of 55 Move to the previous menu Measure setting confirmation can be checked by checking each Tr setting status at the top of each port trace chart In the figure below port 1 is set to VS...

Страница 18: ...Stop Freq of selected port Change Center Freq of selected port Change Span of selected port Move to the previous menu Notice Range of frequency to be setup is as follows 5MHz to 6GHz 3 3 1 STIMULUS CH...

Страница 19: ...is amplitude The range that can be set depends on the Measure setting For VSWR you can set the range from 1 to 65 For Log Mag you can set it from 60dBm to 60dBm Scale menu configuration is shown below...

Страница 20: ...de menu Scale 2 Select Top Bottom Click Top Bottom item Change settings in the input window Port setting after changing item 3 Auto Scale Auto Scale Select the port to execute Click the Auto Scale but...

Страница 21: ...top of each trace chart Sweep Continuous or Single setting function Single SING display on top of each trace chart Run Hold Cont Single setting according to All Port setting Off Individual port settin...

Страница 22: ...PIO Ext Trigger signal transmitted to VIEW950M 3 6 DISPLAY The display includes the number of traces and the ability to go to Windows VIEW950M supports 2 items VSWR Log Mag and 2 traces The display me...

Страница 23: ...s Icon Minimize the program Windows desktop display 3 7 MARKER Up to 6 markers can be set After selecting marker to set it can be displayed on the screen through View setting Normal and Delta markers...

Страница 24: ...ta REF Is Normal type Delta is Ref Show relative to location Marker movement Marker movement with the largest value of the measured value Marker movement Marker move to the smallest value of the measu...

Страница 25: ...Transfer to Single Limit Go to Limit Line Edit Go to Limit Line Edit setting Close switch to Marker menu state 3 7 1 MARKER SETUP MOVING 1 Select Marker Select marker number to set in the Marker Selec...

Страница 26: ...enu of VIEW950M Calibration is as below Display Calibration menu When clicked move to upper menu VIEW950M Enter Calibration progress mode Select Calibration kit types OSL or Electronic Calibration kit...

Страница 27: ...itialization Active Port or All Port Move to the previous menu 3 9 1 LIMIT DISPLAY ACCORDING TO EACH MENU SETTING The display according to each menu setting of the Limit menu is as follows Limit Limit...

Страница 28: ...it line in case of limit line on Limit Limit Line Edit Limit line setting in Limit line edit Limit type can be Max Min Single available Limit Limit Alarm Buzzer Sound output according to Pass Fail res...

Страница 29: ...h the next measurement result That is the reference measurement result and the like can be stored in the memory and can be compared with the current measurement result the measurement condition is cha...

Страница 30: ...ge 30 of 55 Move to the previous menu 3 10 1 TRACE DATA MEM DISPLAY 1 Copy Data to Memory Select port and Tr Perform Copy Data to Memory 2 Data Mem setup Select Data Mem in data display Indicate both...

Страница 31: ...nly in designated folder The menu of VIEW950M Save is as shown below and the saving screen appears when each menu is clicked Display Save menu When clicked move to upper menu VIEW950M Save Trace data...

Страница 32: ...ing over time or when used by multiple people If requiring saving for a long time it is recommended to save it as a file using Save As 3 11 2 SAVE FILE TYPE If requiring saving or copying a file for a...

Страница 33: ...Config Save As If saving to internal memory you can save to the specified path only If saving to USB memory create VIEW950M SaveData folder and select VIEW950M SaveData Trace VIEW950M SaveData Screen...

Страница 34: ...r 3 12 LOAD Load serves as a function of loading each file stored in 3 11 Save Like save it supports both slot method and file method Load Config Apply information saved in Save Config to equipment Lo...

Страница 35: ...Instrument Inc Page 35 of 55 3 12 1 SLOT LOAD Slot Load is a function to load a slot saved by Slot Save That is Save Trace Save Screen and Save Config load each file stored in Load Trace Slot Load Scr...

Страница 36: ...950M Multi Scan INNO Instrument Inc Page 36 of 55 3 12 2 FILE LOAD If clicking the load below each load menu load window appears Load Trace Load Load Screen Load Load Config Load Load Window is as fol...

Страница 37: ...cted the name of the selected file is specified in the File field and OK is loaded Rename Delete etc at the bottom operate as below with File Management function Normal Active Explanation Change the n...

Страница 38: ...System menu allows you to set basic information such as information and language of equipment The system menu of VIEW950M is composed as shown below Display system menu When clicked move to upper men...

Страница 39: ...e communication IP You can set the IP of the device through the LAN setting below System LAN 3 13 2 UPGRADE Upgrade supports both FW Firmware and GUI Each upgrade procedure is as follows 1 FW Upgrade...

Страница 40: ...I Upgrade warning Click the File Select Upgrade button at the bottom of Upgrade screen Warning window pop up Click OK 3 GUI Upgrade GUI file Upgrade If you click OK in the above warning window a searc...

Страница 41: ...View950M Multi Scan INNO Instrument Inc Page 41 of 55 3 13 3 INFORMATION If selecting System Information information window will appear as below to check the basic information of the device...

Страница 42: ...View950M Multi Scan INNO Instrument Inc Page 42 of 55 4 TEST METHOD...

Страница 43: ...nt including Stimulus Scale When changing some setting parameters you have to perform calibration again Therefore before proceeding with the calibration check the frequency setting of each port 2 Sele...

Страница 44: ...nnect Open to the selected port of the mechanical calibration kit After connecting Open to the port click the Open Icon as shown on the left Click to open calibration as below Connection Progress Comp...

Страница 45: ...e real port and connect the load After connecting the load cal kit to the port click the Load Icon as shown on the left Load calibration is performed as below Connection Progress Completion 4 Current...

Страница 46: ...ration in the same manner with the rest of the ports Complete port 2 Complete port 3 Complete port 4 After completing the port calibration click the Close button to switch to the measurement screen Ca...

Страница 47: ...proceed After calibration is completed verify test When verification is finished Port 1 is in the Cal On state E Cal progress by changing the upper left port of the screen 2 Proceed E Cal 2 port Run...

Страница 48: ...nged to green 4 2 MULTI TARGET TO SINGLE LIMIT PROCEDURE The VIEW950M is designed for the antenna production process and VSWR of each band is measured in most antenna manufacturing process to judge th...

Страница 49: ...y function to set target value and find frequency by VSWR Multi Target runs as follows 1 Enter Multi Target Select multi target in the marker 2 Target Value setup Setup value to be found in the target...

Страница 50: ...w of the trace passing the target value goes up Displays 6 pieces sequentially from the left Display marker at the point where the flow of traces passing target value goes down Displays 6 pieces seque...

Страница 51: ...ransmission is generated and clicked After transmission enable Go to Limit Line Edit 4 Go to Limit Line Edit Perform Go to Limit Line Edit The Limit edit window appears and the points that you have se...

Страница 52: ...View950M Multi Scan INNO Instrument Inc Page 52 of 55 5 WARRANTY INFORMATION...

Страница 53: ...ess Surface as the equipment was sent to INNO instrument Inc All equipment returned for warranty repair must have a valid RMA number issued prior to return and be marked clearly on the return packagin...

Страница 54: ...s in the manner provided hereinabove The purchaser acknowledges that no oral statements purporting to be warranties representations or guarantees of any product from INNO Instrument Inc have been made...

Страница 55: ...www innoinstrument com...