Installation manual
Installation
33
4-7
Installing optional modules
and boards
4-7-1
Installing internal modules
The installation of
Sol-PSTN
,
Sol-3G
and
Sol-LAN/S
optional connectivity modules can be
achieved using the connectors integrated into the PCB board and hooks on the back of the
control panel enclosure.
This operation can be carried out while the control panel is powered (“hot”), without
disconnecting the mains power supply or battery.
1. Open the control panel enclosure.
2. Locate the relative connector and placement for the module concerned.
3. Position the rear side of the module on the appropriate hooks on the back of the enclo-
sure, then push the module downwards until it clicks into place.
4. For hot installation, put the control panel into maintenance mode (
paragraph 4-1-3
Maintenance mode
).
5. Close the control panel.
6. If the control panel is in maintenance mode, reset it to normal operating mode.
+12V GND
Control panel
Generic
load 12V
External
power
supply 13.8V
Generic device
Control
Self-powered
sounder-flasher
Indoor
sounder-
Table 4-7: Sol Control panels - description of parts
A
Securing hooks for Sol-
LAN/S module
B
Terminals for Sol-LAN/S
module
C
Securing hooks for Sol-
PSTN module
D
Terminals for Sol-PSTN
module
E
Securing hooks for Sol-
3G module
F
Terminals for Sol-3G
module
G
Blocking hooks
$
)
'
&
(
*
$
%
Содержание Sol Series