18
Wireless systems
Anti-intrusion control panels
Chapter
3
Wireless systems
All Sol control panels have integrated transceivers and, therefore, can manage the Air-2 two-
way wireless system.
Note
In order to comply with the EN 50131-1 standard the alarm system monitoring time must be less than
120 minutes.
The installer has the choice of 3 transmission channels between modules. This feature allows
you to select the channel in such way as to avoid over-the-air interference between two close-
proximity wireless systems (for example, in two adjoining apartments).
Description of the Air2 system devices:
•
Air2–BS200/50
transceiver module, 50 terminals
•
Air2–BS200/30
transceiver module, 30 terminals
•
Air2–BS200/10
transceiver module, 10 terminals
•
Air2–MC200
magnetic contact with shock and tilt sensor in white or brown
•
Air2–MC300
magnetic contact with two I/O terminals, in white or brown
•
Air2–KF100
4 button remote-control key
•
Air2–Pebble
4 button remote-control key
•
Air2–Ergo
4 button remote-control key
•
Air2–FD100
smoke detector
•
Air2-Aria/W
keypad with graphic display
•
Air2-Hedera
outdoor sounder, in white or chrome effect
•
Air2-DT200T
dual technology curtain detector, in white or brown
•
Air2-XIR200W
PIR detector, range 12m
•
Air2-XDT200W
dual technology detector
•
Air2-UT100
universal transceiver
•
Air2-ODI100W
outdoor wireless dual-infrared detector
•
Air2-OTT100W
wireless triple-technology detector for outdoor use
For the technical descriptions and installation instructions of Air2 devices, refer to the manuals
included in the respective packages.
Note
The Air2 devices are certified by IMQ-Sistemi di sicurezza (Italian certification body).
The information relating to the power-supply batteries required by Air2 devices is shown in
the Technical Specification table that follows. The manufacturer cannot guarantee the
declared battery life.
ATTENTION!
Do not use batteries other than those indicated by the manufacturer as they may explode.
Used batteries must be disposed of in accordance with the information provided in the leaflet
inside the package.
Table 3-1: Technical specifications of Air2 system
Operating frequency
range
868.0 - 868.6MHz
selectable channels
868.1, 868.3, 868.5MHz
RF output power
25mW e.r.p.
Communication type
Two-way
Modulation
GFSK
Device monitoring
from 12 to 250 minutes