6
General information
User’s Manual
1-3
Environmental Conditions
The JOY/GR, JOY/MAX, nCode/G, Concept/G, IB100, FLEX5, Nexus and nBy/X
peripheral devices are for indoor installation only and operate best under the
following environmental conditions:
•
Temperature
:
from -10° to +40°C
•
Maximum humidity
:
75% (without condensation)
•
Environmental class
:
II
The nBy/S reader is suitable for indoor or outdoor installation, and operates best
under the following conditions:
•
Temperature
:
from -25° to +70°C
•
Maximum humidity
:
93% (without condensation)
•
Protection grade
:
IP 34
•
Environmental class
:
IV
1-4
Products certified and
conforming to directives
When duly programmed, the SmartLiving intrusion control panel and the devices
described in this manual have been certified by the IMQ - Security Systems
agency as compliant with CEI 79-2:1998+Ab:2000, CEI EN 50131-3:2009 and
CEI EN 50131-6:2008.
The Control panel enclosure houses the following certified devices:
•
INIM Electronics switching-power supply
•
Mother board (IN082 or IN088)
•
SmartLogos30M voice board (accessory item)
•
FLEX5/U input/output expansion board (accessory item)
•
AUXREL32 relay board (accessory item)
•
SmartLAN/SI and SmartLAN/G LAN interface boards (accessory items)
•
IB100/RU BUS isolator board (accessory item)
•
ProbeTH thermal-probe kit for battery-charge optimization (accessory item)
•
TamperNO tamper-protection kit (accessory item)
•
Backup battery, 12 V @ 17 Ah
•
Motherboard (IN082 and IN088) integrated Type B notification apparatus
The control panel compliancy is also guaranteed when connected to the following
certified devices:
•
FLEX5/P input/output expansion boards
•
Joy/MAX, Joy/GR, Concept/G, nCode/G keypads
•
nBy/S outdoor-mount proximity readers
•
nBy/X universal-mount proximity readers
•
IB100/RP BUS isolator
•
Self-powered IB100/A BUS isolator
•
nCard access-control card for proximity readers
•
nTag access-control tag for proximity readers
Compliancy is not guaranteed when the control panel is connected to the
following uncertified devices:
•
SmartLink/GWB GSM interface with 12V @ 1.2 Ah battery
•
BUS-connected Nexus interface
•
BUS connectable Ivy-B, Ivy-BF, Ivy-BM, and Ivy-BFM self-powered
sounderflashers for outdoor installation
•
Wireless devices such as: AIR2, AIR2-BS100 (transceivers), Air2-IR100 (PIR
detectors), Air2-MC100 (magnetic contacts), Air2-KF100 (access-control
keyfobs)
•
SmartModem100 Teleservice modem
TYPE B NOTIFICATION
APPARATUS
ATS2 notification apparatus (refer to EN50131-1:2008-02, paragraph 8.6
Notification, Table 10, page 46, Grade
3
and EN50136) characterized by:
•
Transmission time - classification D2 (60 seconds)
•
Transmission time - max. values M2 (120 seconds)
•
Classification time - classification T2 (25 hours)
•
S0 Substitution security (no detection of device substitution)
•
I0 Information security (no detection of message substitution)