A momentary key-switch or non-latching remote control receiver may
be connected to any zone to allow remote arm/disarm and remote
panic capability.
When using a key-switch or remote control unit a 3K3 resistor
must be connected between the zone input and ground.
Use only a
spring-loaded momentary
key-switch or
non-latching
remote control unit.
r
e
v
i
e
c
e
R
e
t
o
m
e
R
S
D
I
.
9
An IDS Remote Receiver (PN 860-06-0002) may be connected to the
keypad bus. Using this facility allows remote arming and disarming of
the panel while providing user identification for a maximum of 238
remotes. It is possible to assign multiple remotes to a single user.
a
t
a
D
l
a
c
i
n
h
c
e
T
l
a
n
o
i
t
i
d
d
A
.
0
1
A suitable transformer with an output voltage of 16 volts
AC
±10% with a 16VA minimum rating must be used. A 32 VA
transformer is recommended for larger installations.
A 12V sealed lead acid battery with a minimum capacity of 7AH
must be used. The back up period after mains failure will depend