All zones must be end-of-line supervised. Any unused zones
must be terminated with a 3K3 resistor.
The end of line resistor must be placed inside or as close to the
sensor as possible.
If neither zone doubling nor tamper by zone are required the 3K3
resistor must be used.
For zone doubling or tamper per zone, the 4K7 and 12K end-of-
line resistors must be connected as per Figures 2 and 3.
n
o
it
c
e
n
n
o
C
e
n
o
Z
r
e
p
r
e
p
m
a
T
.
2
e
r
u
g
i
F
Tamper operation is as follows:
If the panel is unarmed and a tamper condition occurs, the
siren will not sound but a tamper condition will be reported.
If the panel is armed and a tamper condition occurs an
audible alarm will register and a tamper condition will be
reported.
Panic zones always register panic and tamper conditions.
The colour codes for the 12K and 4K7 resistors are as per
in Figure 4.