IDS1632 INSTALLER MANUAL
IDS1632 INSTALLER MANUAL NO. 700-256-02C ISSUED JUNE 2005 VER 1.01
11
on the number of keypads, sensors and peripheral devices
connected to the system.
The panel can supply a total continuous current of 750mA to
peripheral devices such as keypads, remotes, receivers, passives
etc.
Connect a 12 volt self driven siren or piezo siren [not a horn
speaker] to the siren output.
n
o
i
t
c
e
n
n
o
C
r
e
t
t
i
m
s
n
a
r
T
o
i
d
a
R
.
1
1
When connecting a radio transmitter utilize the TX terminal provided
on the P.C.B to supply power to the transmitter. (See Figure 1) This
output is protected by the 4 Amp battery fuse.
h
c
t
i
w
S
t
e
s
e
R
e
r
a
w
d
r
a
H
.
2
1
Should the need arise to return the panel to factory default, utilise the
hardware reset switch (see Figure 1).
The panel may be defaulted as follows. Remove both battery and AC
power from the panel. While depressing the reset switch reapply power
to the panel by either connecting the battery or the a.c. power.
Release the reset switch approximately 2 seconds after reapplying the
power. Factory default values will now be restored to all locations and
all attached keypad I.Dís will be defaulted.
Note:
Once the reset switch has been disabled by programming a
10 into location 444 it will no longer be possible to default
the panel using the reset switch. The panel can only be
defaulted if a valid installer code is entered and a value of [0]
is entered into location 0.
s
d
a
p
y
e
K
g
n
i
l
l
o
r
n
E
.
3
1
A new panel supplied from the factory will have factory default values in
all locations (as indicated throughout this manual). Similarly new
keypads will have no ID assigned to them. It is however good practice
to default the system by using the reset switch prior to
commencement of programming. This will ensure that the above is
true and that no factory test values remain.