Mains Failure. Entering a value of [1][1] into location 71 will cause the
Panel Prog Output 1 to be set (latched) low in the event of an AC
Mains Restoral.
When programming a programmable output whose action is fixed only
a single digit need be entered. This digit references the programmable
output number (Table 6).
Example:
Programming a value of [10] into Sublocation 42 of Location 129 will
cause the Zone Expander Programmable Output 2 to follow the Siren
Output for Partition 2.
Note:
When connecting any device with a high current requirement
to a programmable output a suitable relay must be used. DO
NOT connect such devices directly to the programmable
outputs as this may damage the output circuitry.