48
700-398-01J X-Series User Manual Issued for version 2.8x
L OCAT ION 165
N o Move me nt Auto Arm T ime Out (de fault = 000 0)
If no violations are registered for the period of time specified in this location then the alarm will auto arm.
This may be used if you forget to arm when leaving for work; the alarm will then automatically away arm itself
if no violations were registered.
This function is only available if values have been programmed into locations 166 and 167.
This No Movement Auto Arm event reports a close event, using user number 133, but only if CID or SIA
reporting has been selected.
Enter a 2-digit duration in hours for each of the 8 partitions and program as a 16-digit string, followed by the
[*] key.
[Maintenance Code] [*] [1] [6] [5] [*] [PARTITION NO.] [*] [HHMM] [*]
The valid data range is: 00h00m to 23h59m. Partition no. is: 1-8.
NOTE: If this location is disabled, then by default, locations 166 and 167 will also be disabled.
L OCAT ION 166
N o Move me nt Auto Arm Star t (de fault = 0000)
Program the start time to start checking for no movement. For example, if you leave your premises at 06:50
am, program the start time to be 07:00.
Enter a 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string, followed by the [*]
key. The valid data range: 00h00m – 23h59m. Partition no. is: 1-8.
[Maintenance Code] [*] [1] [6] [6] [*] [PARTITION NO.] [*] [HHMM] [*]
L OCAT ION 167
N o Move me nt Auto Arm E nd (de fault = 2400)
Program the end time to stop checking for no movement. For example, using 07:00 programmed into location
166 and if 2 hours is needed, then program 09:00.
Enter a 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string, followed by the [*]
key. The valid data range: 00h00m – 23h59m. Partition no. is: 1-8.
[Maintenance Code] [*] [1] [6] [7] [*] [PARTITION NO.] [*] [HHMM] [*]
L OCAT ION 168
N o Move me nt Me dic al Alarm T ime Out (de fault = 0000)
If no movement is detected, while the panel is disarmed, for the period of time specified in this location then
the alarm will activate and report a medical alarm event if programmed by the installer.
This function is only available if values have been programmed into locations 169 and 170.
EXAMPLE:
This may be used to monitor for elderly people who have suddenly become incapacitated and are unable to
sound the panic.
Enter a 2-digit duration in hours for each of the 8 partitions and program as a 16-digit string, followed by the
[*] key.
[Maintenance Code] [*] [1] [6] [9] [*] [PARTITION NO.] [*] [HHMM] [*]
The valid data range is: 00h00m to 23h59m. Partition no. is: 1-8.
NOTE: If this location is disabled, then by default, locations 169 and 170 will also be disabled and not report.
L OCAT ION 169
N o Move me nt Me dic al Alarm Start (de fault = 0100)
The start time can be set for when you know that the person will be awake and active.
Program the start time to start checking for movement. For example, you expect a person to be awake at 6 am,
program the start time to be 06:00.
Enter 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string, followed by the [*] key.
[Maintenance Code] [*] [1] [6] [9] [*] [PARTITION NO.] [*] [HHMM] [*]
The valid data range: 00h00m – 23h59m. Partition no. is: 1-8.
L OCAT ION 170
N o Move me nt Me dic al Alarm E nd (de fault = 0100)
Program the end time to stop checking for movement. For example, using 06:00 programmed into location 169
and if 2 hours is needed, then program 08:00.
Enter a 4-digit time [HHMM] for each of the 8 partitions and program as a 32-digit string, followed by the [*]
key. The valid data range: 00h00m – 23h59m. Partition no. is: 1-8.
[Maintenance Code] [*] [1] [7] [0] [*] [PARTITION NO.] [*] [HHMM] [*]