17
700-398-01J X-Series User Manual Issued for version 2.8x
9.
User Program Mode
LED Keypad
Hold down the [*] key until the beep, then enter [MASTER CODE] [*] [PROGRAMMABLE OPTION] [*]
1.
Ensure that the panel is not armed.
2.
Hold down the [*] key until the keypad buzzer sounds.
3.
The ARM and READY LEDs will alternate flashing.
4.
Enter a [MASTER USER CODE]. The factory default is 1234. Should the [MASTER USER CODE] be
defaulted to 6 digits, it will be 123456. Press the [*] key. A long confirmation beep will sound.
5.
If steps 1 to 4 are performed correctly, the READY LED will flash. If an invalid code was entered, the
keypad buzzer will give an error beep. (3 short beeps). If the error beep occurs, press the [#] key (this
clears all previous entries) and repeat steps 2-4.
6.
Select a programmable option from Table 5.
EXAMPLE:
To add a new user code, enter the User Program Mode by completing steps 1 - 4 as listed above.
To access Option 0, enter a value of [0] (See Table 5) followed by the [*] key.
Enter a [NEW USER CODE] followed by the [*] key. Once the user code is programmed, enter the next code
followed by the [*] key. To exit user program mode press the [#] key.
LCD Keypad
1.
Ensure that the panel is not armed.
2.
Hold down the [*] key until the keypad buzzer sounds.
3.
The LCD display reads ‘Master Code + *’. The factory default is [1234]. Should the MASTER USER CODE
be set to six digits it will be [123456] by default.
4.
Enter the [MASTER USER CODE], followed by the [*] key. A valid entry will be confirmed by a long beep.
If an invalid MASTER USER CODE was entered, the keypad buzzer will give an error beep (3 short beeps).
5.
The first menu option – ‘Option Menu’, ‘Add User Code’ is displayed by default.
6.
Select a programmable option from User Program Options. One may use the [PANIC] or [MED] keys to
scroll through the menu options.
7.
Confirm the entry by pressing the [*] key. A valid entry is confirmed by a long beep. An invalid entry will
be signalled by means of an error beep (3 short beeps). If an error beep occurs, press the [#] key to clear
all previous entries, and repeat steps 2 – 6.
EXAMPLE:
To add a new user code, enter User Program Mode by completing steps 2 - 4 as listed above. Menu Option 0
will be displayed on the LCD screen by default. Press the [*] key to confirm your entry. Once prompted to
‘Enter a User Code’, input a [NEW USER CODE] followed by the [*] key. Once the user code is programmed,
enter the next code followed by [*]. To exit the program mode press the [#] key.
Add a New User Code – Option 0
LED Keypad
Hold down the [*] key until the beep, then enter [MASTER CODE] [*] [0] [*] [NEW USER CODE] [*]
1.
Enter the User Program Mode as per steps 1 to 4 in section 0.
2.
Press the [0] key followed by the [*] key to select the programmable option 0 (zero).
3.
The READY and ARM LEDs flash simultaneously.
4.
Enter the [NEW USER CODE] followed by the [*] key.
5.
The READY and ARM LEDs flash simultaneously.
6.
Further codes may be added by repeating step 4.
7.
Press the [#] key to exit the current option.
8.
Press the [OPTION NUMBER] followed by the [*] key for the next option, or the [#] key again to exit user
programming.
LCD Keypad
1.
Enter the User Program Mode as per steps 1 - 4 of section.
2.
The LCD display reads ‘Option Menu’, ‘Add User Code’. This is the programmable option required, press
the [*] key.
3.
The LCD display reads ‘New Code + *’.
4.
Enter [NEW USER CODE] followed by the [*] key.