700-398-01J X-Series User Manual Issued for version 2.8x
NOTE:
If output action 0 is chosen, then LEDs 1 and 2 will be off.
If output action 1 is chosen, then LED 1 will be on.
If output action 2 is chosen, then LED 2 will be on.
If output action 3 is chosen, then LEDs 1 and 2 will be on.
The Programmable Output Code in User Code Properties – Option 10, must be enabled in order for the
user outputs to work.
Table 7: Output Actions Data
Table 8: Output Address Physical Mapping Data
Address
Physical Outputs
Address
Physical Outputs
00
Disabled
14 - 15
Zone expander 5 output 1 & 2
01 - 05
Onboard output 1 - 5
16 – 17 Zone expander 6 output 1 & 2
06 - 07
Zone expander 1 output 1
& 2
18 - 25
Output Expander 1 Outputs 1 - 8
08 - 09
Zone expander 2 output 1
& 2
26 - 33
Output Expander 2 Outputs 1 - 8
10 - 11
Zone expander 3 output 1
& 2
34 - 41
Keypad 1 output - Keypad 8 output
12 - 13
Zone expander 4 output 1
& 2
42 - 57
Xwave
2
I/O Modules 1 - 16
10.
Xwave
2
Bi-directional Wireless
Wireless Bi-Directional Remote Identification
This menu option allows for the identification of the bi-directional remote.
1.
Enter the Master User Menu: Hold down [*] for 3 seconds.
2.
Enter the Master code: [1][2][3][4] [*].
3.
Scroll using the [Panic >>] key to “Identify BD Rmt” menu or enter [1][4][*].
4.
Press a button on the bi-directional remote.
5.
The LCD will indicate the hub and slot number for that remote. Slot number is the user code learnt to the
remote.
Wireless Bi-directional Device Battery Check
Each Xwave
2
detectors battery voltage can be checked via the keypad to determine if the batteries will require
changing in the near future giving you peace of mind when going away on holiday.
The system will begin to notify you of a low battery, when the battery voltage reaches 2.5V.
To check battery voltage of a device:
1.
Enter the Master User Menu: Hold down [*] for 3 seconds.
2.
Enter the Master code: [1][2][3][4] [*].
3.
Scroll using the [Panic >>] key to “View Bidir Batt” menu or enter [1][5][*].
4.
Enter the hub number whose devices you want to check: [1][*].
5.
Scroll using the [Panic >>] or [Medical <<] keys to the zone.
NOTE: The battery voltage of the device allocated to the zone must be changed when they have reached 2.5V
or before.
Value
Output Action
Value
Output Action
00
Set Output High (Set)
02
Pulse Output High
01
Set Output Low (Reset)
03
Pulse Output Low