TEMPERATURE/RESISTANCE CHART
IF COMPRESSOR
THEN
A. Has Auto Start/Stop Prom
No Changes Required
B. Does Not Have Auto Start/
Install Auto Start/Stop
Stop Prom
Field Kit 39666672
TOOLS REQUIRED:
ONLY WHAT WOULD BE FOUND IN ANY REASONABLY EQUIPPED
SERVICEMAN’S TOOL BOX.
PARTS LIST (KIT P/N 39674387)
ITEM
PART NUMBER
QTY
DESCRIPTION
1
39813274
1
INTERFACE I, SEQUENCER
2
39547880
1
CABLE, MODULAR, 44" LG.
3
39177357
4
SCREW, #10-32 SELF TAPPING
4
39178611
4
SCREW, #10-24
5
39128533
4
NUT, #10-24
6
APDD 403A-91
1
INSTRUCTIONS, INTERFACE I
INSTALLATION
7
APDD 405A-91
1
INSTRUCTIONS, SEQUENCE
CONTROLLER, SSR 10-450 HP
8
39181284
1
FUSE, 1A (SPARE)
SUBJECT: TESTING SOFTWARE WITH A SEQUENCER
Connect a sequencer to a compressor. Follow the following steps for testing
software with a sequencer.
1) Start the compressor.
2) Put the compressor into the ON/OFF LINE mode.
3) Set the sequencer to load and unload at pressures lower than the current
settings of the controller.
4) Start the sequencer. The unit should begin to load and unload at the
sequencer’s pressure settings.
5) Stop the sequencer. The unit should load and unload at the controller’s
pressure settings.
6) Start the sequencer. The unit should begin to load and unload at the
sequencer’s pressure settings.
7) Disconnect the sequencer. The unit should load and unload at the
controller’s pressure settings.
8) Connect the sequencer. The unit should load and unload at the
sequencer’s pressure settings.
If the unit has AUTO START/STOP, do steps 9 and 10.
9) Close discharge valve so the unit will unload. Wait for the amount of time
that the auto restart timer is set for. When this time has expired, the unit
should shut off.
10) Open the discharge valve. The line pressure should drop and the unit
should restart. The unit should load and unload at the sequencer’s
pressure settings.
11) Stop the sequencer and the compressor.
52
19171
53
18658
54
18161
55
17679
56
17211
57
16757
58
16317
59
15889
60
15475
61
15072
62
14681
63
14301
64
13933
65
13575
66
13227
67
12890
68
12562
69
12244
70
11934
71
11634
72
11342
73
11058
74
10782
75
10514
76
10254
77
10000
78
9754
79
9515
80
9282
81
9055
82
8835
83
8621
84
8413
85
8210
86
8013
87
7821
88
7635
89
7453
90
7277
91
7105
92
6937
93
6774
94
6616
95
6461
96
6311
97
6165
98
6022
99
5883
100
5748
101
5616
102
5488
103
5363
104
5241
105
5123
106
5007
107
4894
108
4784
109
4677
110
4573
111
4472
112
4372
113
4276
114
4182
115
4090
116
4000
117
3913
118
3828
119
3745
120
3663
121
3584
122
3507
123
3432
124
3359
125
3287
126
3218
127
3150
128
3083
129
3019
130
2955
131
2894
132
2833
133
2775
134
2717
135
2661
136
2607
137
2553
138
2501
139
2450
140
2400
141
2352
142
2304
143
2258
144
2213
145
2169
146
2125
147
2083
148
2042
149
2001
150
1962
151
1924
152
1888
153
1849
154
1813
155
1778
-38-
-37-
DEGREE
F. TEMP. RES.
0
89768
1
86914
2
84161
3
81503
4
78938
5
76463
6
74072
7
71765
8
69536
9
67384
10
65306
11
63298
12
61359
13
59485
14
57674
15
55924
16
54233
17
52598
18
51017
19
49490
20
48012
21
46584
22
45202
23
43865
24
42573
25
41322
26
40112
27
38941
28
37808
29
36712
30
35650
31
34623
32
33631
33
32668
34
31736
35
30834
36
29960
37
29114
38
28295
39
27501
40
26733
41
25988
42
25267
43
24568
44
23891
45
23235
46
22599
47
21983
48
21385
49
20806
50
20244
51
19699
DEGREE
F. TEMP. RES.
DEGREE
F. TEMP. RES.
Содержание Intellisys SSR 10-40
Страница 32: ...29...
Страница 33: ...30...
Страница 72: ...70 FIGURE 1 INTERFACE MOUNTING LOCATION FIGURE 2 INTELLISYS CONTROLLER FIGURE 3 WIRING DIAGRAM 69...
Страница 73: ...70 FIGURE 1 INTERFACE MOUNTING LOCATION FIGURE 2 INTELLISYS CONTROLLER FIGURE 3 WIRING DIAGRAM 69...
Страница 74: ...71...
Страница 75: ...72...
Страница 76: ...72...
Страница 103: ...99 100 NOTES NOTES...
Страница 104: ...99 100 NOTES NOTES...
Страница 105: ...101 102 NOTES NOTES...
Страница 106: ...101 102 NOTES NOTES...