IM PO R TA N T: D o N O T use latches on cover to force filter into air cleaner. U sing cover to force
filter w ill dam age cleaner housing.
7. Close housing with dust unloader valve aim ed down and latch latches.
IM PO R TA N T:
W henever the air cleaner has been serviced or cover has been rem oved, A LW A YS
fully depress the air restriction indicator reset button (if equipped) to assure
accurate readings.
8. If equipped, fully depress air restriction indicator reset button and release to reset indicator.
Cleaning the Radiator and the Fan Blades
Radiator:
Clogging of the cooling system depends on engine operating conditions. Risk of clogging will increase
due to oil and fuel residues, which can settle on the engine. Therefore, in very dusty environments, make
sure that the engine is free from oil leaks. Heavy clogging can happen when working conditions on sites
are particularly dusty.
Cleaning:
Put a container under the radiator to collect dirt and debris.
Cleaning with compressed air:
Clean the radiator with compressed air taking particular care with the cooling fins.
Rinse with water to remove the remaining dirt.
Cleaning with a cleaner/grease remover:
Spray the radiator with a cold water high pressure cleaner, then wait about tem
minutes for the cleaner to impregnate.
Clean with a strong water jet without directing the jet to the engine’s sensitive
components such as the alternator, cabling, electronic components etc.
Use compressed air when cleaning the engine.
Warm up the engine to evaporate the remaining water.
Fan Blades
Remove the fan guard.
Clean the fan blades with a clean cloth. Change the fan if the axial and radial play is
excessive or if the blades are cracked.
Refit the fan guard.
Checking the injectors
This operation requires special knowledge and use of special tools, contact your local Ingersoll-Rand
dealer for this service.