Triton Go Product Manual |
Wiring and Connections
INGENIA | 05/29/2017
99
7.6.4 Step and direction
For this command source, the drive typically accepts two digital inputs from an external source: Step (pulse)
and Direction. Direction signal sets the direction of rotation (i.e., logic low or "0" for clockwise rotation and logic
high or "1" for counter-clockwise rotation). Pulse signal is usually a square signal and each pulse on this signal
causes the controller to move the motor one step in that direction. This command source can be used only for
position mode.
This command source is interfaced through high-speed digital inputs. HS_GPI1 is used for Step input, and
HS_GPI2 is used for Direction input. Refer to
for further specifications about high-
speed digital inputs. Next figures illustrate how to connect a single ended and differential step and direction
command source to the Triton Go Servo Drive.