Triton Go Product Manual |
Signalling LEDs
INGENIA | 05/29/2017
51
The EtherCAT green and red
LEDs (shared with CAN communication) indicate the EtherCAT state machine
status. The green LED is the
RUN LED
, and the red LED is the
ERROR LED
. Next table shows their states
meaning:
RUN LED
state
EtherCAT slave status
ERROR LED
state
EtherCAT slave status
Off
INIT
Off
No error
Blinking
PRE-OPERATIONAL
Blinking
Invalid configuration
Single Flash
SAFE-OPERATIONAL
Single flash
Local error
On
OPERATIONAL
Double flash
Watchdog timeout
On
Application controller failure
For high severity errors inside the Triton Go Servo Drive, an special LED state has been developed:
Status
Signalling
RUN LED
state
ERROR LED
state
Internal error
Interleaved blink
Blinking (Initial status: OFF)
Blinking (Initial status: ON)
The two yellow LEDs at the sides are the
LINK 0
and
LINK 1
LEDs. The
LINK LEDs
indicates the state of the
EtherCAT physical link activity:
LINK LED state
Slave State
Off
Port closed
Flickering
Port opened (activity on port)
On
Port opened (no activty on port)
External LEDs
The user can connect external LEDs by means of LED_RUN_K, LED_ERR_K, LED_LINK1_K and
LED_LINK0_K pins in the
. These LEDs shall behave exactly the same
as described above.