Warning, power supply and motor terminals can have dangerous voltages in excess to 50 V and cause electric
shock. Never touch them directly while in operation. The end installation must ensure that these terminals are
not accessible.
Recommended section wire is 2.5 mm
2
~ 5.3 mm
2
, AWG 10 ~ AWG 13. Adapt the cable diameter to the worst-case
current needs.
It is recommended to use flexible silicone or Teflon cables with high-temperature ratings
≥
180 ºC. The diameter
of the cable jacket (insulator) should be less than 5.08 mm to prevent collision between wires.
The cables must always be mechanically secured after soldering.
When using power supply only (no logic supply) it is recommended to connect pins 27 (+LOG_SUP) and 29
(GND_D) of I/O connector J2 together.
7.3.
Motor
P2 connector
2.6 mm diameter gold plated solder pads or flying leads option. Pad pitch is 5.08 mm.
Pin
Signal
Function
Warning! Risk of electric shock!
1
PH_A
Motor phase A
2
PH_B
Motor phase B
3
PH_C
Motor phase C
4
PE
Protective earth connection, internally connected to standoffs and drive housing.
Notes
Warning, power supply and motor terminals can have dangerous voltages in excess to 50 V and cause electric
shock. Never touch them directly while in operation. The end installation must ensure that these terminals are
not accessible.
Recommended section wire is 2.5 mm
2
~ 5.3 mm
2
, AWG 10 ~ AWG 13. High-temperature materials are necessary
(
≥
180 ºC).
The cables must be mechanically secured after soldering.
For long cables, it is essential to use a shielding connected to protective earth at both ends of the cable.
More information
Check the
section for further information on how to connect the Everest
XCR to a power supply and motor.
Содержание 2147502492
Страница 31: ...Everest XCR Product manual Connectors Guide INGENIA 2020 10 01 00 04 38 31 Image TE B 155 9001...
Страница 72: ...Everest XCR Product manual Wiring and Connections INGENIA 2020 10 01 00 04 38 72...
Страница 85: ...Everest XCR Product manual Installation INGENIA 2020 10 01 00 04 38 85...