Everest XCR - Product manual |
Wiring and Connections
INGENIA | 2020-10-01 00:04:38
60
Specification
Value
ESD capability
IEC 61000-4-2 (ESD) ± 30 kV (air), ± 30 kV (contact)
IEC 61000-4-5; tp = 8/20
μ
s 12 A, 200 W
Maximum voltage range
-0.5 ~ 5.5 V
Maximum recommended working
frequency
5 kHz
1st order filter cutting frequency (-3dB)
16 kHz
Sampling frequency
10 ksps
Type of sensors
Open collector
Logic output
Push-pull output
Pull-up resistor value
1 k
Ω
Next figures show the typical waveforms of the
digital Halls signals.
Next figure illustrates how to connect the digital Halls to Everest XCR and a simplified input schematic.