24
Chapter 3 - Inputs-Outputs
XtrapulsCD1-pm
– Installation manual
SPECIFICATION OF THE ENCODER OUTPUT SIGNALS
6 - X4: COMMAND CONNECTOR
8 pins male connector (with 5.08 mm pitch) - Same connector for all drive types in 230 V and 400 V.
Female connector supplied.
Fastening torque of the connector screws: 0,5 Nm.
PIN
SIGNAL
I/O
REMARK
1, 2
AOK and AOK/
O
Relay contact: closed when drive OK
Pmax = 10 W with Umax = 50 V or Imax = 100 mA
3
ENABLE
I
Positive optocoupled logic
4
Limit
I
Positive optocoupled logic
5
Limit switch -
I
Positive optocoupled logic
6
INDEX
I
Positive optocoupled logic
7
GND: 0 V of logic inputs
I
Potential reference of the optocoupled (galvanic
isolated) logic inputs. This potential reference may be
different from the auxiliary supply
8
RESET
I
Positive optocoupled logic : Inhibition of the faults
memory stored in the drive
6.1 - SPECIFICATIONS OF THE LOGIC INPUTS: FC+, FC-, INDEX, ENABLE, RESET
These inputs are optocoupled and work in positive logic.
100 KΩ
The input voltage corresponding to level 1
is between 18 V and 30 V
100 KΩ
Logic input
0 V
CD1-pm
5 V
8.2 K
100 nF
+5 V
X3- 5
X3- 18
Driver
75-176
+5 V
X3- 6,7
X3- 19,20
Driver
75-176
+5 V
3.3 K
200 R
200 R