Analogue inputs and outputs (AIO)
The XtracontrolEC22 has up to 12 analogue inputs (AI) and 6 analogue outputs (AO) on plugs X4, X5 and X6. The
layout of the I/O is identical on all 3 plugs.
The following counterpieces have been tested for the SC-SMT 3.81 (Weidmüller) plug-in connector and are
approved for use with the XtracontrolEC22:
Weidmüller BCZ 3.81/14/180 (F,LH,LR)
Weidmüller BCF 3.81/14/180 (F,LH,LR)
Phoenix FK-MCP 1,5/14-ST-3,81-LR
Abb. 9: analogue inputs and outputs plugs X4, X5 and X6 (Weidmüller SC-SMT 3.81/14/180 LF 3.2)
Analogue inputs and outputs plugs X4, X5 and X6
Pin
X4
X5
X6
Assignment
1
AI 1
AI 5
AI 9
U/T; ±10 V; PT100/1000
2
AI 1
AI 5
AI 9
I; ±20 mA
3
–
–
–
AGND
4
AI 2
AI 6
AI 10
U; 0–10 V
5
AI 2
AI 6
AI 10
I; ±20 mA
6
–
–
–
AGND
7
AI 3
AI 7
AI 11
U/T; ±10 V; PT100/1000
8
AI 3
AI 7
AI 11
I; ±20 mA
9
–
–
–
AGND
10
AI 4
AI 8
AI 12
U; 0–10 V
11
AI 4
AI 8
AI 12
I; ±20 mA
12
–
–
–
AGND
13
AO 1
AO 3
AO 5
U; 0–10 V
14
AO 2
AO 4
AO 6
U; 0–10 V
Analogue channel wiring
Ensure the following connection requirements are met so as to guarantee the measuring accuracy of the device:
▶
Use analogue cables with a braided shield.
▶
Separate the laying of analogue cables and power cables. Where required, install metallic shielding in cable
channels.
▶
Earth the screen at the place where it enters the control cabinet.
▶
Connect the screen close and directly with AGND.