Safety Precautions
Safety Precautions
Read these instructions carefully before you install, operate, or transport the system.
Install the rack cabinet and the associated equipment at a site where the ambient
temperature stays lower than 35
°
C.
Install the power source socket outlet near the enclosure where it is easily
accessible and ground the rack cabinet.
Secure airflow clearance inside and around the rack cabinet.
- Secure at least an 18 to 20cm clearance on the rear side of the enclosure.
- Do not cover enclosure openings.
- Route the cables inside the rack cabinet.
- Do not leave the drive bays empty. Always install drive trays even if without a
hard drive otherwise it will affect airflow efficiency of the enclosure.
Secure each enclosure module using its retaining screws.
Put the power cords and other cables away from foot traffic. Do not place items
over power cords and make sure they do not rest against data cables.
Install all modules to the enclosure before powering on the system.
Should a module fail, leave it in its place until you have the replacement item
on-hand to take its place.
Ensure that the correct power range is being used before powering the device.
None of the covers or replaceable modules should be removed during operation.
If the enclosure is not used for a long time, disconnect it from mains to avoid
transient over-voltage.
For power source redundancy, please make sure that the two PSUs are plugged
into two different power sources (ie. to different circuit breakers).
Compatibility Notice
The use of Infortrend certified components is strongly recommended to ensure
compatibility, quality and normal operation with your Infortrend products. Please
contact your distributor for a list of Infortrend certified components (eg. SFP, SFP+,
HBA card, iSCSI cable, FC cable, memory module, etc.).