Figure 2-15. Video Input Connections
2.4.2 Control Connections
The system cannot perform PTZ (PAN/TILT/ZOOM) control
without control signal transferring. V2040 provides PTZ controls
via the V2411 series Control Code Generator/Distributors. A single
V2411 can provide Manchester control code outputs for control of
up to 64 site cameras. Multiple V2411 distributors can be cascaded
to control a maximum of 1024 site cameras. Please refer to relevant
manuals for further details on V2411.
To select appropriate control signal cables, please refer to the
following table.
Table 2-13. Individually-Shielded, Twisted-Pair Cable &
Maximum Operating Distance
Cable Type
Max. Operating Distance
Belden 9406
5000 ft (1500m)
Belden 9402
5000 ft (1500m)
Belden 8723
8000 ft (2400m)
Belden 8162
15,000 ft (4600m)
Belden 9729
15,000 ft (4600m)
V2411
V1690
V2040
Dataline
Control signal cable
Coaxial
Cable
Super
dome
DATALINE
RS232 PORTS
ETHERNET PROG MON
1
2
1
2
3
4
5
6
7
8
9
10
11
IN
OUT
DATALINE
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
B W S B W S B W S B W S
177
161
145
129
113
97
81
65
49
33
17
1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D
A
T
A
B
U
F
F
E
R
DATALINE
IN
OUT
EXT
SYNC
IN
OUT
POWER
W S B
+R
E
F
PAN
1
P
O
T
PAN
2
P
O
T
TI
LT
P
O
T
FO
C
U
S
P
O
T
ZO
O
M
P
O
T
-R
E
F
SH
IE
LD
AU
X1
N
/C
AU
X1
N
/O
AU
X1
C
O
M
AU
X2
N
/C
AU
X2
N
/O
AU
X2
C
O
M
24
V
A
C
24
V
A
C
PO
WER
CO
DE
IN
OUT
Control signal
cable
RISK OF
ELECTRIC SHOCK
DO NOT OPEN
CAUTION
Figure 2-16. Control Connections with V2411, V1690M and Super
Dome
2.4.3 Video Output Connections
A single Video Output Module provides four monitor outputs (see
System Module Description - Video Output Module
in this chapter).
To connect a monitor to its video output terminal:
1.
Properly install the monitor according to relevant manuals.
2.
Identify the monitor with a desired monitor number, and then
identify the BNC terminal on a VOM module rear panel that
designates the same monitor number. (See
Module Setup - Video
Output Module Switches
in this chapter.)
3.
Connect the monitor to the associated BNC terminal connector
with a video cable.
4.
Set the monitor's termination to 75 ohm.
To select appropriate coaxial cables, please refer to Table 2-12.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Mon1
Mon3
Mon5
Mon7
Mon2
Mon4
Mon6
Mon8
Mon16
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
177
161
145
129
113
97
81
65
49
33
17
1
DATA LINE
RS232 PORTS
ETHERNET PROG MON
1
2
1
2
3
4
5
6
7
8
9
10
11
D
A
T
A
B
U
F
F
E
R
DATA
LINE
IN
OUT
EXT
SYNC
IN
OUT
POWER
CAUTION
RISK OF
ELECTRIC SHOCK
DO NOT OPEN
Figure 2-17. Video Output Connections
2.4.4 Alarm Input Connections
Alarm inputs are provided by the V2431 series Alarm Interface
Units (AIUs) connected to V2040 external CPU. Each V2431 AIU
can handle a maximum of 64 alarms, and up to 16 units can be
cascaded together to provide a total of 1024 alarms. To perform
alarm input connections with V2431:
1.
Route wires from a RS-232 port on V2040's rear panel to the
OUTPUT port on V2431's rear panel.
2.
Route wires from site sensors to their associated alarm input
connectors on V2431's rear panel. Each sensor requires two wires
- one connecting the alarm input terminal and the other
connecting the ground terminal.
Note:
The V2431 is set to Normally Open (N.O.) as a factory
default.
3.
If the system requires more than 64 alarm inputs, cascade
multiple V2431 AIUs to expand the system's alarm input