Model
CHAMPION
6 places
CHAMPION
4 places
CHAMPION
4 places
ELITE - FACE 2
2 places
POWER JETS
4 places
POWER JETS
6 places
XTRA
4 places
XTRA
6 places
XTRA
4 places
Article no. EU
7505548
7505549
7505550
7505551
7505552
7505553
7505554
7505555
7505556
Format
square
square
square
square
square
square
round
round
round
Number of persons
6
4
4
2
4
6
4
6
4
Water capacity
910 litres
600 litres
600 litres
1000 litres
600 litres
910 litres
800 litres
1000 litres
800 litres
Voltage / frequency
AC 220-240V / 50Hz
Rated power
1.800 W
1.800 W
1.800 W
1.800 W
2.320 W
2.580 W
1.800 W
1.800 W
1.800 W
External dimensions
185 x 185 cm 154 x 154 cm 154 x 154 cm 198 x 198 cm 154 x 154 cm
185 x 185 cm
Ø 1.80 m
Ø 2.08 m
Ø 1.80 m
Internal dimensions
140 x 140 cm 110 x 110 cm 110 x 110 cm 158 x 158 cm
110 x 110 cm
140 x 140 cm
Ø 1.40 m
Ø 1.65 m
Ø 1.40 m
Height
65 cm
65 cm
65 cm
65 cm
65 cm
65 cm
65 cm
65 cm
65 cm
Filter pump (AC 12 V / 50 Hz)
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
1.400 l/h
Air blower (AC 220-240V / 50 Hz)
600 W
600 W
600 W
600 W
600 W
600 W
600 W
600 W
600 W
Motor Hydrojets (AC 220-240V / 50 Hz)
4 x 130 W
6 x 130 W
Heater (AC 220-240V / 50 Hz)
1.200 W
1.200 W
1.200 W
1.200 W
1.200 W
1.200 W
1.200 W
1.200 W
1.200 W
Power cable
3.3 m H07RN-F 3*1.00mm² with a plug fitted with an RCD
Temperature range
20°C-40°C
20°C - 40°C 20°C - 40°C
20°C - 40°C
20°C - 40°C
20°C - 40°C
20°C - 40°C
20°C - 40°C
20°C - 40°C
Temperature rise
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
1-1,5 °C/h
Inegrated air beds
2
Number of air jets
130
120
120
110 + 30
120
130
120
130
120
Number of massage jets
4
6
Weight of SPA filled with water
(without persons)
936 kg
621 kg
622 kg
1033 kg
631 kg
949 kg
821 kg
1025 kg
822 kg
Delivery contents
Whirlpool/SPA
1
1
1
1
1
1
1
1
1
LED light for Infinite®Spa
1
1
Underlay pad
1
1
1
1
1
1
1
1
1
Whirlpool cover (PVC laminate polyester
with isolation coating)
1
1
1
1
1
1
1
1
1
Filling and drainage hose
1
1
1
1
1
1
1
1
1
Filter cartridge with cover
2
2
2
2
2
2
2
2
2
Rubber plug (air outlet)
1
1
1
1
1
1
1
1
1
Transport bag
1
1
1
1
1
1
1
1
1
Repair kit (PVC patches, adhesive)
1
1
1
1
1
1
1
1
1
1
Safety
This device has been manufactured in accordance with the latest technology and current safety regulations. Nevertheless, this SPA can
cause injury or damage to people and property if the device is not used for its intended purpose or if the health & safety instructions are
ignored.
READ AND FOLLOW WITH THESE INSTRUCTIONS BEFORE YOU START USING THE SPA!
1.1 Private use
This SPA is intended exclusively for private use.
CAUTION
As a SPA owner, you must comply with local and national legislation in relation to child safety, safety barriers and other safety
requirements. Please contact your local planning department for further details.
1.2 Child safety
DANGER
Risk of drowning. It is vitally important to ensure that children never have access to the SPA without supervision.
To prevent accidents, you must make sure that children are always supervised when using the SPA.
CAUTION
Make sure that children are not left unsupervised in the vicinity of the SPA.
- Fit a self-closing door, a lockable gate, fence or a child safety gate.
- After using the SPA, cover it with the insulated cover provided.
CAUTION
To minimise the risk of injury, do not allow children to use this SPA without supervision.
1.3 Electricity and risk of electric shock
WARNING:
Maintenance and repair work on the electrical components and any replacement of the power cord may only be carried out by a
qualified electrician.
WARNING
The SPA is fitted with an RCD (residual current device or ground fault circuit interrupter) on the end of the power cable. The RCD
must be tested each time before using the SPA. Do not use the SPA if the RCD is not working properly. Unplug the power cable until the fault
has been identified and rectified. Contact a qualified electrician to correct the fault. Do not bypass or open the RCD. The RCD must be easily
accessible and visible; it must be positioned at least 1.5 m away from the SPA.
WARNING
The SPA must not be connected via an external switching device such as a timer switch or to an external power circuit that is
switched on and off at certain times by a power supply.
WARNING
The power supply must be in accordance with the product specifications. Do not switch on the device if the power supply does not
comply with the specified regulations! You can obtain further information from your local qualified electrician. The power supply circuit must
be protected with a residual current device (GFCI or RCD) with a maximum residual current rating of 30 mA.
WARNING
: Risk of electric shock. If the SPA is placed at a distance of less than 1.5 m from metal surfaces, then each of these me
tal surfaces must be connected to a solid copper wire (at least 1mm2) with the grounding terminals located at the bottom
of the powerbox.
WARNING
Risk of electric shock. Do not use any extension cables to connect to the power supply.
WARNING
Risk of electric shock. Install the SPA at least 1.5 m away from all metallic surfaces. Metal parts must be permanently connected to
the earth connection by means of a solid copper wire.
WARNING
Risk of electric shock. It is not permitted to place or operate lighting installations, radios, TVs or other electrical devices within a
radius of 1.5 m of the SPA.
WARNING
Risk of electric shock. Do not use the SPA when it is stormy or raining.
WARNING
Always disconnect the power plug before you clean, remove or service the product or make any other adjustments.
WARNING
The power cable must not be buried in the ground. Position the cable so that it cannot be damaged by lawn mowers, hedge
clippers or other devices.
WARNING
If the power cable of this device is damaged, it must be replaced by a qualified electrician.
1.4 Filter cartridges and suction
If a filter cartridge is defective or missing, long hair or body parts can be sucked into the supply pipe, which can lead to serious accidents.
Children are particularly vulnerable to injuries and must be protected from the hazards. Prevent the risk of injuries by observing the following
rules:
- Never operate the SPA if the filter cartridge is defective or not attached.
- A defective filter cartridge must be replaced immediately. Make sure that when parts are replaced, only original part are used
Manual SPA 2/4/6 2020_2.indd 47
Manual SPA 2/4/6 2020_2.indd 47
30.09.20 17:21
30.09.20 17:21