ATTENTION!!

Read this manual carefully before installing the MicroTimer 2400!

Mains connection

Guarentee

Security

Before connecting the appliance to the mains, check that the mains supply voltage corresponds to the voltage
printed on the type plate of the adapter. If the mains voltage is different, consult your supplier.

No guarantee can be given if safety regulations are not followed.

Always disconnect the power supply before handling anything inside the device.

This device is in conformity with the EMC directive and low-voltage directive.

CE Conformité Europeène (Conform European Norm)

WEEE Directive (Waste of Electrical and Electronic Equipment)

Inepro considers it important to properly take the climate into account. We therefore produce as many
climate-friendly products. Your new device contains materials which can be recycled and then reused. At the
end of life, specialized companies can dismantle the device, to materials which can be reused in order to
recycle and reuse. For example, the materials that must be discarded will be limited to a minimum. Please
take into account the rules and regulations in your area regarding the rules about disposal of packaging
materials, exhausted bateries and old equipment. 

Thank you, Inepro BV

This device may only be used indoors.

Indoor User Only

Directives

Due to continuous product improvements this manual is subject to change without notice. This document
describes the technical and functional operation of the MicroTimer 2400. Greatest care has been taken drafting
the information in this manual and it may be said that it is reliable. However, the producer is not liable for any
shortcomings in the text or incompleteness of the information. Thank you for your decision to use the
MicroTimer 2400.

This document:

Содержание MicroTimer 2400

Страница 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...

Страница 2: ......

Страница 3: ...ttp www inepro com Table of Contents 1 Introduction 2 1 Design 2 Extra functioning 3 2 Versions 5 Possebilities 6 1 Basic functioning 7 Settings 8 1 Function Menu 8 2 Function Overview 15 Specificatio...

Страница 4: ......

Страница 5: ...new device contains materials which can be recycled and then reused At the end of life specialized companies can dismantle the device to materials which can be reused in order to recycle and reuse For...

Страница 6: ......

Страница 7: ...Introduction PartI...

Страница 8: ...rior time During the prior time the length of the main time will be shown intermittently on the display During the prior time it is possible to reduce the main time if necessary The prior time can als...

Страница 9: ...3 Versions De versies There is one type of MicroTimer available as the functioning of the MicroTimer mainly depends on the additional software modules and the settings...

Страница 10: ......

Страница 11: ...Possebilities PartII...

Страница 12: ...ting a coin or by means of a continuous external drive Output The MicroTimer output is programmable It may be chosen between the standard continue output which means that both relays are activated dur...

Страница 13: ...Settings PartIII...

Страница 14: ...use key Up or the Stop key Down 7 Quit and confirm the set value by pressing the Start Pause key Up and the Stop key Down simultaneously The function menu is shown again and another function can be se...

Страница 15: ...umulatively the total main time Value Description Default 1 255 Max number of coins 1 Note The v alue of this setting has to be at least 1 Function F5 Minimum amount of coins ECOS module EM 05 Functio...

Страница 16: ...ay 1 activity T he value of this register represents the number x 1000 minutes e g 5 5000 minutes When the counter reaches zero the message will appear on the display T his is the standard message to...

Страница 17: ...ter is read back to front as follows C ounter index Example V alue 1 1 2 3 3 7 4 5 5 0 6 0 In this example the total running time amounts to 005731 minutes V alue 1 0 2 0 3 0 4 0 5 0 6 0 Note Resettin...

Страница 18: ...sec p m 800 849 30 sec p m 400 449 22 sec p m 850 899 30 sec p m The time adjustment is preprogrammed and depend on the maximum number of running hours set in F6 F7 This table shows the prolongation...

Страница 19: ...during the main time Function Pause during the main time Setting Description Default 00 Pause during the main time disabled 1 01 Pause during the main time enabled note During a pause situation the r...

Страница 20: ...yment during main time Function Payment during main time Setting Description Default 00 Pay ment during main time is disabled 0 01 Pay ment during main time is enabled note The maximum amount of coin...

Страница 21: ...Specifications PartIV...

Страница 22: ...nsumption 25 mA maximaal Fuse 500mA Supply voltage for the low voltage model Voltage range A C 12 V A C 24 V A C Voltage range DC 12 V DC 35 V DC Stroomopname 250 mA maximum Outputs Maximum rupturing...

Страница 23: ...Appendix PartV...

Страница 24: ...three button from a greater distance maximum 50 meters E O utput 2 O utput 2 is exclusiv ely switched by the main time function F1 The relay s are potential free or dry ie they are simply switches tha...

Страница 25: ...tput signal depends on the settings in Functie P0 Connection diagram with external connections and a live output Use this diagram to connect one or two devices A B that must be fed by the main 230V AC...

Страница 26: ...ection diagram with external connections and uncharged neutral output Use this diagram to connect one or two devices A B that relays power to one of their outputs and must be electronically fed trough...

Страница 27: ...on print 2 Quick start function Dip switches ON blocked OFF activated 4 Enable disable the Start button 3 Enable disable the Timer button 2 Enable disable the Stop button 1 Enable disable the Function...

Страница 28: ......

Отзывы: