2    -    MicroTimer 2400

Introduction

 Introduction

The MicroTimer® standard control board design includes a minimum of functionality. The functionality of the MicroTimer®
can be expanded by means of additional “ECOS”® software modules. Thus, it is possible to produce perfectly customised
MicroTimers®.  MicroTimer®  outputs  have  two  neutral  relay  points  to  control  a  connected  device  over  a  certain
programmable length of time. This MicroTimer® is programmed in a user-optimised way by means of three control keys.
With its potted electronics and its extensibility by means of “ECOS”® software modules the MicroTimer® is a very special
timer of its kind.

 “ECOS”® : Electronic Customised Option System

 Design

§

Very resistant plastic housing

§

Suitable for internal and external installation

§

Three keys: Start/Pause, Timer & Stop (internal and external)

§

Bright green 2-digit LED display

§

Extensibility by means of ECOS software modules

§

Supply voltage either 24 Volt or 240 Volt

 Extra werking (with all ECOS modules)

The MicroTimer® can be activated with three freely programmable time-segments. The duration of  these  time-segments
can be set at 0 to 255 minutes.

 Prior Time

The MicroTimer® starts with a prior time. During the prior time the length of the main time will be shown intermittently on
the display. During the prior time it is possible to reduce the main time if necessary. The prior time can also be bypassed so
that the main time will start automatically.

 Time per periode (Main Time)

During the main time the remaining time will be shown on the display.  When  activating  a  pause  a  buzzer  signal  may  be
generated.  Another  possibility  consists  of  the  automatic  main  time  adjustment  based  on  the  progression  of  the  service
counter.

 Post Time

The main time is automatically followed by the post time. During the post time 

“Cl” (cool) is displayed. After the post

time it is possible to activate a clean function, in this case 

“CL”  is displayed intermittently. This clean function inhibits

the MicroTimer®. Furthermore, there is an “after start” function by means of which an extra main time of 30 seconds can
be given at the end of the whole session.

 Service Message

Registration facilities, as for example start, running time and service counters can also be used. The start and running time
counters  may  either  be  activated  as  counters,  which  can  be  reset,  or  as  cumulative  counter,  which  can  not  be  reset.
Automatic representation of the Running time counter is affected by pressing the Stop key during  3  seconds.  The  service

counter generates a 

SR (service message) on the display

Содержание MicroTimer 2400

Страница 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...

Страница 2: ......

Страница 3: ...ttp www inepro com Table of Contents 1 Introduction 2 1 Design 2 Extra functioning 3 2 Versions 5 Possebilities 6 1 Basic functioning 7 Settings 8 1 Function Menu 8 2 Function Overview 15 Specificatio...

Страница 4: ......

Страница 5: ...new device contains materials which can be recycled and then reused At the end of life specialized companies can dismantle the device to materials which can be reused in order to recycle and reuse For...

Страница 6: ......

Страница 7: ...Introduction PartI...

Страница 8: ...rior time During the prior time the length of the main time will be shown intermittently on the display During the prior time it is possible to reduce the main time if necessary The prior time can als...

Страница 9: ...3 Versions De versies There is one type of MicroTimer available as the functioning of the MicroTimer mainly depends on the additional software modules and the settings...

Страница 10: ......

Страница 11: ...Possebilities PartII...

Страница 12: ...ting a coin or by means of a continuous external drive Output The MicroTimer output is programmable It may be chosen between the standard continue output which means that both relays are activated dur...

Страница 13: ...Settings PartIII...

Страница 14: ...use key Up or the Stop key Down 7 Quit and confirm the set value by pressing the Start Pause key Up and the Stop key Down simultaneously The function menu is shown again and another function can be se...

Страница 15: ...umulatively the total main time Value Description Default 1 255 Max number of coins 1 Note The v alue of this setting has to be at least 1 Function F5 Minimum amount of coins ECOS module EM 05 Functio...

Страница 16: ...ay 1 activity T he value of this register represents the number x 1000 minutes e g 5 5000 minutes When the counter reaches zero the message will appear on the display T his is the standard message to...

Страница 17: ...ter is read back to front as follows C ounter index Example V alue 1 1 2 3 3 7 4 5 5 0 6 0 In this example the total running time amounts to 005731 minutes V alue 1 0 2 0 3 0 4 0 5 0 6 0 Note Resettin...

Страница 18: ...sec p m 800 849 30 sec p m 400 449 22 sec p m 850 899 30 sec p m The time adjustment is preprogrammed and depend on the maximum number of running hours set in F6 F7 This table shows the prolongation...

Страница 19: ...during the main time Function Pause during the main time Setting Description Default 00 Pause during the main time disabled 1 01 Pause during the main time enabled note During a pause situation the r...

Страница 20: ...yment during main time Function Payment during main time Setting Description Default 00 Pay ment during main time is disabled 0 01 Pay ment during main time is enabled note The maximum amount of coin...

Страница 21: ...Specifications PartIV...

Страница 22: ...nsumption 25 mA maximaal Fuse 500mA Supply voltage for the low voltage model Voltage range A C 12 V A C 24 V A C Voltage range DC 12 V DC 35 V DC Stroomopname 250 mA maximum Outputs Maximum rupturing...

Страница 23: ...Appendix PartV...

Страница 24: ...three button from a greater distance maximum 50 meters E O utput 2 O utput 2 is exclusiv ely switched by the main time function F1 The relay s are potential free or dry ie they are simply switches tha...

Страница 25: ...tput signal depends on the settings in Functie P0 Connection diagram with external connections and a live output Use this diagram to connect one or two devices A B that must be fed by the main 230V AC...

Страница 26: ...ection diagram with external connections and uncharged neutral output Use this diagram to connect one or two devices A B that relays power to one of their outputs and must be electronically fed trough...

Страница 27: ...on print 2 Quick start function Dip switches ON blocked OFF activated 4 Enable disable the Start button 3 Enable disable the Timer button 2 Enable disable the Stop button 1 Enable disable the Function...

Страница 28: ......

Отзывы: