12 - MicroTimer 2400
Settings
Function FE, Coin counter (reset impossible)
(
ECOS module EM-12)
Function
C oin counter ( r eset possible) T his counter r epr oduces the number of coins.
Setting
Descr iption
Default
0-6
Reading procedure as in
function F B
.
0
N ote:
C ounter can't be reset, procedure like in
function F B
.
Function FF, TAT (Automatic main time adjustment)
(
ECOS module EM-11)
Function
T A T ( A utomatic main time adjustment) A ctivating this function, the main time
is automatically adjusted on the basis of the ser vice counter pr ogr ession ( F6 &
F7 ) . If one of the two ser vice counter s is pr ogr ammed again the T A T function
has to be r eset again as well.
Setting
Descr iption
Default
00
TA T function disabled
1
01
TA T function enabled
note:
Running hour s
P r olongation per
minute
Running hour s
P r olongation per
minute
0 – 49
+ 0 sec p/m
450 – 499
+ 24 sec p/m
50 – 99
+ 3 sec p/m
500 – 549
+ 27 sec p/m
100 – 149
+ 5 sec p/m
550 – 599
+ 30 sec p/m
150 – 199
+ 8 sec p/m
600 – 649
+ 30 sec p/m
200 – 249
+ 11 sec p/m
650 – 699
+ 30 sec p/m
250 – 299
+ 14 sec p/m
700 – 749
+ 30 sec p/m
300 – 349
+ 16 sec p/m
750 – 799
+ 30 sec p/m
350 – 399
+ 19 sec p/m
800 – 849
+ 30 sec p/m
400 – 449
+ 22 sec p/m
850 - 899
+ 30 sec p/m
The time adjustment is preprogrammed and depend on the maximum number of running hours
set in
F 6
&
F 7
. This table show s the prolongation per range of running hours.
Function P0, Output configuration
Function
O utput configur ation. Relay output type.
Setting
Descr iption
Default
00
S ignal output, w hich is activ e throughout the w hole session.
0
01
P ulse output, w hich is briefly activ e/generating a pulse in the beginning of the
main time and in the beginning of the post time.
note:
This diagram
show s the
response of the
relay s at the signal
and pulse setting.
Function P1, External drive facility
Function
Exter nal dr ive facility
Setting
Descr iption
Default
00
S tarting the M icoTimer happens through a short pulse on the timer button or
coin input (D epending on menu
F A
)
0
01
S tarting the M icoTimer happens by an external dev ice. This dev ice controls
the main time. In case the signal is activ e, then also the timer is activ e,
unless the set time has ended. Interrupting the activ e signal w ill put the
M icoTimer in post-time (w hen enabled). The controls is depending on the
setting in menu
F A
(remote button print input or coin mechanism input).
note:
This setting must be set on 0 for this dev ice.
11
11
10
10
11
11
Содержание MicroTimer 2400
Страница 1: ...2019 Inepro B V All rights reserved Technical Manual MicroTimer 2400 MicroTimer 2400...
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 7: ...Introduction PartI...
Страница 10: ......
Страница 11: ...Possebilities PartII...
Страница 13: ...Settings PartIII...
Страница 21: ...Specifications PartIV...
Страница 23: ...Appendix PartV...
Страница 28: ......